Download this file

PDS_VERSION_ID       = PDS3                                                  
DATA_SET_ID          = "PVO-V-OMAG-3--SCCOORDS-HIRES-V1.0"                   
RECORD_TYPE          = STREAM                                                
OBJECT               = TEXT                                                  
   PUBLICATION_DATE  = 2022-10-14                                            
   NOTE              = "ERRATA.TXT reflects any known deficiencies           
                        with files contained on this volume."                
END_OBJECT           = TEXT                                                  
END                                                                          
                                                                             
Users are encouraged to provide comments back to the PPI Node of the PDS     
if errors or omissions are found either in data or in documentation.         
Please send comments by e-mail or U.S. mail to the PPI Node PDS Operator:    
                                                                             
  Email             pds_operator@igpp.ucla.edu                               
                                                                             
                                                                             
                                  ERRATA                                     
                                                                             
This file contains a list of all deficiencies and irregularities that are    
known to exist at the time of production of this volume.                     
                                                                             
Data Errors                                                                  
===========                                                                  
                                                                             
     MAG HIGH RES ASCII (STANDARD_DATA_PRODUCT_ID = "PVO MAG HR ASCII")      
     ------------------------------------------------------------------      
     Previous versions of these data files (PRODUCT_VERSION_ID = 1) have     
     contained bad Bz VSO data values. The data values tended to be hover    
     around 0 nT and a B-field magnitude computed from the VSO B-field       
     components did not match the B-field magnitude (BT) values that were    
     included in with the data.                                              
                                                                             
     Version 2.0 of this data set includes new versions of some of the data  
     products. Previous versions (PRODUCT_VERSION_ID = 1) of the MAG high    
     resolution ASCII data files (STANDARD_DATA_PRODUCT_ID =                 
     'PVO MAG HR ASCII') contained bad Bz VSO data values. The data values   
     tended to be hover around 0 nT and a B-field magnitude computed from    
     the VSO B-field components did not match the B-field magnitude (BT)     
     values that were included in with the data. These data were regenerated 
     with the VSO coordinates recalculated from the spacecraft coordinates   
     (SC) B-field using the PVO VSO spin axis information contained in the   
     PVO VSO Ephemeris data set (PVO-V-POS-5--VSOCOORDS-12SEC-V1.0) to       
     to perform the coordinate rotation. The ASCII SC data were taken        
     directly from the binary version of the data (STANDARD_DATA_PRODUCT_ID =
     'PVO MAG HR BINARY'), though data values greater than 1000. nT or less  
     than -1000. nT were set to flag values. In addition the ancillary       
     engineering (ENGR) and instrument status (INSTSTAT) were regenerated    
     setting bad data to flag values. The original, unflagged data values    
     are available in the binary version of the same data.                   
                                                                             
Non-standard practices                                                       
======================                                                       
                                                                             
     The PDS standards do not specify where to store the required MD5        
     checksum file for a volume.  We have placed it in the root directory of 
     the volume with the file name "CHECKSUMS.TXT".  This may be considered  
     invalid by some verifiers.