/* L1_CNTR.FMT */
/* This file defines the structure of the L1 Counter Tables */
INTERCHANGE_FORMAT = ASCII
ROW_BYTES = 137 /* Includes ❮CR❯❮LF❯ */
COLUMNS = 13
OBJECT = COLUMN
NAME = CHANNEL
COLUMN_NUMBER = 1
START_BYTE = 2
BYTES = 2
DATA_TYPE = ASCII_INTEGER
DESCRIPTION = "The channel number from 0-35."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = CHANNEL_NAME
COLUMN_NUMBER = 2
START_BYTE = 6
BYTES = 6 /* Does NOT include double quotes */
DATA_TYPE = CHARACTER
DESCRIPTION = "The channel name (ID)."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = FAST
COLUMN_NUMBER = 3
START_BYTE = 14
BYTES = 10
DATA_TYPE = ASCII_INTEGER
UNIT = "Counts"
DESCRIPTION = "The fast trigger counts."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = SLOW
COLUMN_NUMBER = 4
START_BYTE = 25
BYTES = 10
DATA_TYPE = ASCII_INTEGER
UNIT = "Counts"
DESCRIPTION = "The slow trigger counts."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = DURATION
COLUMN_NUMBER = 5
START_BYTE = 36
BYTES = 10
DATA_TYPE = ASCII_INTEGER
UNIT = "Seconds"
DESCRIPTION = "The time duration (secs) the detector was active."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = ALIVE_PERCENT
COLUMN_NUMBER = 6
START_BYTE = 47
BYTES = 8
DATA_TYPE = ASCII_REAL
UNIT = "Percent"
DESCRIPTION = "
The percent the detector was active during the observation.
(The duration divided by the total observation time.)
"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = FAST_DAC
COLUMN_NUMBER = 7
START_BYTE = 56
BYTES = 10
DATA_TYPE = ASCII_INTEGER
UNIT = "N/A"
DESCRIPTION = "The baseline fast trigger threshold."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = SLOW_DAC
COLUMN_NUMBER = 8
START_BYTE = 67
BYTES = 10
DATA_TYPE = ASCII_INTEGER
UNIT = "N/A"
DESCRIPTION = "The baseline slow trigger threshold."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = FAST_ACTUAL
COLUMN_NUMBER = 9
START_BYTE = 78
BYTES = 11
DATA_TYPE = ASCII_INTEGER
UNIT = "N/A"
DESCRIPTION = "The actual fast trigger setting."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = SLOW_ACTUAL
COLUMN_NUMBER = 10
START_BYTE = 90
BYTES = 11
DATA_TYPE = ASCII_INTEGER
UNIT = "N/A"
DESCRIPTION = "The actual slow trigger setting."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = INPUT_GAIN
COLUMN_NUMBER = 11
START_BYTE = 102
BYTES = 10
DATA_TYPE = ASCII_INTEGER
UNIT = "N/A"
DESCRIPTION = "The input gain setting."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = FAST_SHAPER
COLUMN_NUMBER = 12
START_BYTE = 113
BYTES = 11
DATA_TYPE = ASCII_INTEGER
UNIT = "N/A"
DESCRIPTION = "The fast shaper gain setting."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = SLOW_SHAPER
COLUMN_NUMBER = 13
START_BYTE = 125
BYTES = 11
DATA_TYPE = ASCII_INTEGER
UNIT = "N/A"
DESCRIPTION = "The slow shaper gain setting."
END_OBJECT = COLUMN
/* End of L1_CNTR.FMT */
|