Download this file

/* L1_CNTR.FMT  */                                                            
/* This file defines the structure of the L1 Counter Tables */                
                                                                              
 INTERCHANGE_FORMAT      = ASCII                                              
 ROW_BYTES               = 137   /* Includes ❮CR❯❮LF❯ */                      
 COLUMNS                 = 13                                                 
                                                                              
  OBJECT           = COLUMN                                                   
    NAME           = CHANNEL                                                  
    COLUMN_NUMBER  = 1                                                        
    START_BYTE     = 2                                                        
    BYTES          = 2                                                        
    DATA_TYPE      = ASCII_INTEGER                                            
    DESCRIPTION    = "The channel number from 0-35."                          
  END_OBJECT       = COLUMN                                                   
                                                                              
  OBJECT           = COLUMN                                                   
    NAME           = CHANNEL_NAME                                             
    COLUMN_NUMBER  = 2                                                        
    START_BYTE     = 6                                                        
    BYTES          = 6           /* Does NOT include double quotes */         
    DATA_TYPE      = CHARACTER                                                
    DESCRIPTION    = "The channel name (ID)."                                 
  END_OBJECT       = COLUMN                                                   
                                                                              
  OBJECT           = COLUMN                                                   
    NAME           = FAST                                                     
    COLUMN_NUMBER  = 3                                                        
    START_BYTE     = 14                                                       
    BYTES          = 10                                                       
    DATA_TYPE      = ASCII_INTEGER                                            
    UNIT           = "Counts"                                                 
    DESCRIPTION    = "The fast trigger counts."                               
  END_OBJECT       = COLUMN                                                   
                                                                              
  OBJECT           = COLUMN                                                   
    NAME           = SLOW                                                     
    COLUMN_NUMBER  = 4                                                        
    START_BYTE     = 25                                                       
    BYTES          = 10                                                       
    DATA_TYPE      = ASCII_INTEGER                                            
    UNIT           = "Counts"                                                 
    DESCRIPTION    = "The slow trigger counts."                               
  END_OBJECT       = COLUMN                                                   
                                                                              
  OBJECT           = COLUMN                                                   
    NAME           = DURATION                                                 
    COLUMN_NUMBER  = 5                                                        
    START_BYTE     = 36                                                       
    BYTES          = 10                                                       
    DATA_TYPE      = ASCII_INTEGER                                            
    UNIT           = "Seconds"                                                
    DESCRIPTION    = "The time duration (secs) the detector was active."      
  END_OBJECT       = COLUMN                                                   
                                                                              
  OBJECT           = COLUMN                                                   
    NAME           = ALIVE_PERCENT                                            
    COLUMN_NUMBER  = 6                                                        
    START_BYTE     = 47                                                       
    BYTES          = 8                                                        
    DATA_TYPE      = ASCII_REAL                                               
    UNIT           = "Percent"                                                
    DESCRIPTION    = "                                                        
      The percent the detector was active during the observation.             
       (The duration divided by the total observation time.)                  
      "                                                                       
  END_OBJECT       = COLUMN                                                   
                                                                              
  OBJECT           = COLUMN                                                   
    NAME           = FAST_DAC                                                 
    COLUMN_NUMBER  = 7                                                        
    START_BYTE     = 56                                                       
    BYTES          = 10                                                       
    DATA_TYPE      = ASCII_INTEGER                                            
    UNIT           = "N/A"                                                    
    DESCRIPTION    = "The baseline fast trigger threshold."                   
  END_OBJECT       = COLUMN                                                   
                                                                              
  OBJECT           = COLUMN                                                   
    NAME           = SLOW_DAC                                                 
    COLUMN_NUMBER  = 8                                                        
    START_BYTE     = 67                                                       
    BYTES          = 10                                                       
    DATA_TYPE      = ASCII_INTEGER                                            
    UNIT           = "N/A"                                                    
    DESCRIPTION    = "The baseline slow trigger threshold."                   
  END_OBJECT       = COLUMN                                                   
                                                                              
  OBJECT           = COLUMN                                                   
    NAME           = FAST_ACTUAL                                              
    COLUMN_NUMBER  = 9                                                        
    START_BYTE     = 78                                                       
    BYTES          = 11                                                       
    DATA_TYPE      = ASCII_INTEGER                                            
    UNIT           = "N/A"                                                    
    DESCRIPTION    = "The actual fast trigger setting."                       
  END_OBJECT       = COLUMN                                                   
                                                                              
  OBJECT           = COLUMN                                                   
    NAME           = SLOW_ACTUAL                                              
    COLUMN_NUMBER  = 10                                                       
    START_BYTE     = 90                                                       
    BYTES          = 11                                                       
    DATA_TYPE      = ASCII_INTEGER                                            
    UNIT           = "N/A"                                                    
    DESCRIPTION    = "The actual slow trigger setting."                       
  END_OBJECT       = COLUMN                                                   
                                                                              
  OBJECT           = COLUMN                                                   
    NAME           = INPUT_GAIN                                               
    COLUMN_NUMBER  = 11                                                       
    START_BYTE     = 102                                                      
    BYTES          = 10                                                       
    DATA_TYPE      = ASCII_INTEGER                                            
    UNIT           = "N/A"                                                    
    DESCRIPTION    = "The input gain setting."                                
  END_OBJECT       = COLUMN                                                   
                                                                              
  OBJECT           = COLUMN                                                   
    NAME           = FAST_SHAPER                                              
    COLUMN_NUMBER  = 12                                                       
    START_BYTE     = 113                                                      
    BYTES          = 11                                                       
    DATA_TYPE      = ASCII_INTEGER                                            
    UNIT           = "N/A"                                                    
    DESCRIPTION    = "The fast shaper gain setting."                          
  END_OBJECT       = COLUMN                                                   
                                                                              
  OBJECT           = COLUMN                                                   
    NAME           = SLOW_SHAPER                                              
    COLUMN_NUMBER  = 13                                                       
    START_BYTE     = 125                                                      
    BYTES          = 11                                                       
    DATA_TYPE      = ASCII_INTEGER                                            
    UNIT           = "N/A"                                                    
    DESCRIPTION    = "The slow shaper gain setting."                          
  END_OBJECT       = COLUMN                                                   
                                                                              
 /* End of L1_CNTR.FMT */