/* PDS FORMAT FILE FOR RAD ANALOG ELECTRONIC (RAE) HOUSEKEEPING DATA*/

OBJECT             = COLUMN
   NAME            = VIRENA_OUTPUT
   DATA_TYPE       = MSB_UNSIGNED_INTEGER
   START_BYTE      = 1
   BYTES           = 2
   DESCRIPTION     = "ADC (Analog to Digital Converter) reading of
                      VIRENA output."
END_OBJECT         = COLUMN

OBJECT             = COLUMN
   NAME            = ANALOG_GROUND_1
   DATA_TYPE       = MSB_UNSIGNED_INTEGER
   START_BYTE      = 3
   BYTES           = 2
   DESCRIPTION     = "First analog ground ADC (Analog to Digital 
                      Converter) reading." 
END_OBJECT         = COLUMN

OBJECT             = COLUMN
   NAME            = ANALOG_GROUND_2
   DATA_TYPE       = MSB_UNSIGNED_INTEGER
   START_BYTE      = 5
   BYTES           = 2
   DESCRIPTION     = "Second analog ground ADC (Analog to Digital 
                      Converter) reading." 
END_OBJECT         = COLUMN

OBJECT             = COLUMN
   NAME            = ADC_CALIBRATION_HIGH
   DATA_TYPE       = MSB_UNSIGNED_INTEGER
   START_BYTE      = 7
   BYTES           = 2
   DESCRIPTION     = "Voltage that is 1/2 percent from maximum high for ADC"
END_OBJECT         = COLUMN

OBJECT             = COLUMN
   NAME            = ADC_CALIBRATION_LOW
   DATA_TYPE       = MSB_UNSIGNED_INTEGER
   START_BYTE      = 9
   BYTES           = 2
   DESCRIPTION     = "Voltage that is 1/2 percent higher than ADC minimum."
END_OBJECT         = COLUMN

OBJECT             = COLUMN
   NAME            = VOLTAGE_CAL_LOW
   DATA_TYPE       = MSB_UNSIGNED_INTEGER
   START_BYTE      = 11
   BYTES           = 2
   DESCRIPTION     = "Voltage that is 15 mV higher than VOLTAGE_REF_LOW."
END_OBJECT         = COLUMN

OBJECT             = COLUMN
   NAME            = VOLTAGE_REF_LOW
   DATA_TYPE       = MSB_UNSIGNED_INTEGER
   START_BYTE      = 13
   BYTES           = 2
   DESCRIPTION     = "Supply voltages that go to the VIRENA, should be 1.5 
                     units??"
END_OBJECT         = COLUMN

OBJECT             = COLUMN
   NAME            = DAC_REFENENCE
   DATA_TYPE       = MSB_UNSIGNED_INTEGER
   START_BYTE      = 15
   BYTES           = 2
   DESCRIPTION     = "DAC (Digital to Analog Converter) reference to VIRENA 
                      ~3.0V (flight) 1.0V (eng)."
END_OBJECT         = COLUMN

OBJECT             = COLUMN
   NAME            = BIAS_70
   DATA_TYPE       = MSB_UNSIGNED_INTEGER
   START_BYTE      = 17
   BYTES           = 2
   DESCRIPTION     = "Measured bias current for 70 volt supply. "
END_OBJECT         = COLUMN

OBJECT             = COLUMN
   NAME            = POSITIVE_5V_SENSOR
   DATA_TYPE       = MSB_UNSIGNED_INTEGER
   START_BYTE      = 19
   BYTES           = 2
   DESCRIPTION     = "Positivie 5V sensor for RSH."
END_OBJECT         = COLUMN

OBJECT             = COLUMN
   NAME            = NEGATIVE_5V_ANALOG
   DATA_TYPE       = MSB_UNSIGNED_INTEGER
   START_BYTE      = 21
   BYTES           = 2
   DESCRIPTION     = "Negative 5V for analog."
END_OBJECT         = COLUMN

OBJECT             = COLUMN
   NAME            = POSITIVE_5V_ANALOG
   DATA_TYPE       = MSB_UNSIGNED_INTEGER
   START_BYTE      = 23
   BYTES           = 2
   DESCRIPTION     = "Postive 5V for analog."
END_OBJECT         = COLUMN

OBJECT             = COLUMN
   NAME            = TEMPERATURE_4
   DATA_TYPE       = MSB_UNSIGNED_INTEGER
   START_BYTE      = 25
   BYTES           = 2
   DESCRIPTION     = "Temperature for temp_4 thermistor for CDH"
END_OBJECT         = COLUMN

OBJECT             = COLUMN
   NAME            = TEMPERATURE_3
   DATA_TYPE       = MSB_UNSIGNED_INTEGER
   START_BYTE      = 27
   BYTES           = 2
   DESCRIPTION     = "Temperature for temp_3 thermistor.
                      RSH internal temperature - near detector D"
END_OBJECT         = COLUMN

OBJECT             = COLUMN
   NAME            = TEMPERATURE_2
   DATA_TYPE       = MSB_UNSIGNED_INTEGER
   START_BYTE      = 29
   BYTES           = 2
   DESCRIPTION     = "Temperature for temp_2 thermistor.
                      RSH internal temperature - near detector D (opposite
                      side of temp_3)"
END_OBJECT         = COLUMN

OBJECT             = COLUMN
   NAME            = TEMPERATURE_1
   DATA_TYPE       = MSB_UNSIGNED_INTEGER
   START_BYTE      = 31
   BYTES           = 2
   DESCRIPTION     = "Temperature for temp_3 thermistor.
                      RSH internal temperature - near detector A"
END_OBJECT         = COLUMN