/* PDS FORMAT FILE FOR RAD DATA FRAME HEADER */

OBJECT             = COLUMN
   NAME            = FRAME_LENGTH
   DATA_TYPE       = MSB_UNSIGNED_INTEGER
   START_BYTE      = 1
   BYTES           = 4
   DESCRIPTION     = "Length of the frame in bytes."
END_OBJECT         = COLUMN

OBJECT             = COLUMN
   NAME            = CONTROL_AND_STATUS_FLAGS
   DATA_TYPE       = MSB_UNSIGNED_INTEGER
   START_BYTE      = 5
   BYTES           = 4

   OBJECT          = BIT_COLUMN
     NAME          = OPCODE
     BIT_DATA_TYPE = UNSIGNED_INTEGER
     START_BIT     = 1
     BITS          = 8
     DESCRIPTION   = "Opcode."
   END_OBJECT      = BIT_COLUMN

   OBJECT          = BIT_COLUMN
     NAME          = ERROR_CONTROL_TYPE
     BIT_DATA_TYPE = UNSIGNED_INTEGER
     START_BIT     = 9
     BITS          = 2
     DESCRIPTION   = "The type of error control algorithm applied by 
                      the Instrument Transfer Frame. Valid: 
                      0=reserved.
                      1=The CRC error control algorithm was applied
                      and placed in the error control field at the.  
                      end of the frame.
                      2=The Fletcher checksum error control algorithm
                      was applied and placed in the error control 
                      field at the end of the frame.
                      3=No error control algorithm was applied and no
                      error control field is included."
   END_OBJECT      = BIT_COLUMN

   OBJECT          = BIT_COLUMN
     NAME          = DATA_PRESENT_FLAG
     BIT_DATA_TYPE = UNSIGNED_INTEGER
     START_BIT     = 11
     BITS          = 1
     DESCRIPTION   = "Indicatethe presence or absence of both the 
                     Header Field Data Length and the Instrument 
                     Transfer Frame Data Field. A value of 0 
                     indicates the Header Field Data Length and the 
                     Instrument Transfer Frame Data Field are not 
                     present; a value of 1 indicates the Header
                     Field Data Length and Instrument Transfer Frame 
                     Data Field are present."
   END_OBJECT      = BIT_COLUMN

   OBJECT          = BIT_COLUMN
     NAME          = FRAME_TYPE
     BIT_DATA_TYPE = UNSIGNED_INTEGER
     START_BIT     = 12
     BITS          = 1
     DESCRIPTION   = "Frame type.  0=Science Data Frame
                      1=Command Reply Frame"
   END_OBJECT      = BIT_COLUMN

   OBJECT          = BIT_COLUMN
     NAME          = WATCHDOG_TIMER_FLAG
     BIT_DATA_TYPE = UNSIGNED_INTEGER
     START_BIT     = 13
     BITS          = 1
     DESCRIPTION   = "Indicates the watchdog timer has expired.
                      Valid: 0=False, 1=True"
   END_OBJECT      = BIT_COLUMN

   OBJECT          = BIT_COLUMN
     NAME          = TIME_SYNC_FLAG
     BIT_DATA_TYPE = UNSIGNED_INTEGER
     START_BIT     = 14
     BITS          = 1
     DESCRIPTION   = "Indicates if the instrument has not received a
                      time sync command from the RCE and is expecting
                      one. Valid: 0=False, 1=True"
   END_OBJECT      = BIT_COLUMN

   OBJECT          = BIT_COLUMN
     NAME          = BOOT_IMAGE
     BIT_DATA_TYPE = UNSIGNED_INTEGER
     START_BIT     = 15
     BITS          = 2
     DESCRIPTION   = "Identifies the boot image used. Valid: 0=RAM 
                      image, 1=EEPROM, off-nominal boot, 2=PROM"
   END_OBJECT      = BIT_COLUMN

   OBJECT          = BIT_COLUMN
     NAME          = HIGH_PRIORITY_FLAG
     BIT_DATA_TYPE = UNSIGNED_INTEGER
     START_BIT     = 17
     BITS          = 1
     DESCRIPTION   = "High-priority data is stored in RAD NVM. If set,  
                      make INFO EVR, inhibit this flag for the rest of
                      this interaction-session, and continue normally.
                      Valid: 0=False, 1=True"
   END_OBJECT      = BIT_COLUMN

   OBJECT          = BIT_COLUMN
     NAME          = MEMORY_LOAD_FLAG
     BIT_DATA_TYPE = UNSIGNED_INTEGER
     START_BIT     = 18
     BITS          = 3
     DESCRIPTION   = "Indicates that status of the memory load. Valid:
                      0=IDLE, 1=Currently loading to scratch,
                      2=checksum is good, 3=checksum is bad, 
                      4=patching to final destination, 5=verifying 
                      final memory, 6=successful, 7=failed."
   END_OBJECT      = BIT_COLUMN

   OBJECT          = BIT_COLUMN
     NAME          = MEMORY_ERROR_FLAG
     BIT_DATA_TYPE = UNSIGNED_INTEGER
     START_BIT     = 21
     BITS          = 1
     DESCRIPTION   = "Indicates an overall memory error occurred.   
                      Valid: 0=False, 1=True"
   END_OBJECT      = BIT_COLUMN

   OBJECT          = BIT_COLUMN
     NAME          = COMMUNICATION_STRING_ID
     BIT_DATA_TYPE = UNSIGNED_INTEGER
     START_BIT     = 22
     BITS          = 2
     DESCRIPTION   = "Identifies RCE communications string used.   
                      Valid: 0=RCE A, 1=RCE B, 2=BOTH sides occurred."
   END_OBJECT      = BIT_COLUMN

   OBJECT          = BIT_COLUMN
     NAME          = SOLAR_EVENT_STATUS
     BIT_DATA_TYPE = UNSIGNED_INTEGER
     START_BIT     = 24
     BITS          = 1
     DESCRIPTION   = "RAD has detected a rate above the solar event 
                      threshold. 0=normal levels, 1=solar event."
   END_OBJECT      = BIT_COLUMN

   OBJECT          = BIT_COLUMN
     NAME          = WAKE_UP_STATUS
     BIT_DATA_TYPE = UNSIGNED_INTEGER
     START_BIT     = 25
     BITS          = 1
     DESCRIPTION   = "Indicates how instrument woke up. Valid: 
                     0 = nominal wake, internal timer expired.
                     1 = premature wake-up, either initial power on,
                     or line toggle from RCE."
   END_OBJECT      = BIT_COLUMN

   OBJECT          = BIT_COLUMN
     NAME          = MODE_STATUS
     BIT_DATA_TYPE = UNSIGNED_INTEGER
     START_BIT     = 26
     BITS          = 1
     DESCRIPTION   = "Indicates current mode of instrument.
                     Valid: 0=SCIENCE, 1=CHECKOUT"
   END_OBJECT      = BIT_COLUMN

   OBJECT          = BIT_COLUMN
     NAME          = INTERNAL_ISSUES_FLAG
     BIT_DATA_TYPE = UNSIGNED_INTEGER
     START_BIT     = 27
     BITS          = 1
     DESCRIPTION   = "Indicates an internal issue has occurred.  The 
                      observation data should be looked over for
                      messages about the issue.
                      Valid: 0=False, 1=True"
   END_OBJECT      = BIT_COLUMN

   OBJECT          = BIT_COLUMN
     NAME          = COMMAND_CONDITION_CODE
     BIT_DATA_TYPE = UNSIGNED_INTEGER
     START_BIT     = 28
     BITS          = 5
     DESCRIPTION   = "Frame command condition code.  Valid: 0=reserved;
                      1=nominal execution; 2=Indicates a framing error 
                      in the received command.  For a UART port, this 
                      indicates that a byte was received without a 
                      valid stop bit.  For HSS instruments, this 
                      indicates that a frame signal was removed and a 
                      non-integer number of bytes was received. 
                      3=Indicates that the recipient lost data due to 
                      an overrun condition.  Should not happen if flow 
                      control is used and is working properly.4=For 
                      UART port only, indicates that the recipient 
                      detected bad parity on a received byte in a 
                      command.5=unused; 6=Op code not defined for this 
                      instrument; 7=Instrument does not support 
                      specified error control type; 8=unused; 
                      9=Reserved Status Flags are unexpected.
                      10=condition code is not meaningful; 11=Data 
                      present was set, but data length was missing or 
                      zero, or the frame length was inconsistent with
                      the data length field. 12=checksum or crc failed; 
                      13=instrument in the wrong state or mode to 
                      process this command. 14=Invalid, inconsistent or 
                      unexpected data for this opcode; 15=Stop 
                      iterating a command; 16-17=unused; 18=priority
                      data"
   END_OBJECT      = BIT_COLUMN

END_OBJECT         = COLUMN

OBJECT             = COLUMN
   NAME            = DATA_LENGTH
   DATA_TYPE       = MSB_UNSIGNED_INTEGER
   START_BYTE      = 9
   BYTES           = 4
   DESCRIPTION     = "Length in bytes of the data."
END_OBJECT         = COLUMN