Download this file

PDS_VERSION_ID          = PDS3                                                
/* File written: 2020/06/12 12:13:33 */                                       
MISSION_NAME            = "JUNO"                                              
SPACECRAFT_NAME         = "JUNO"                                              
INSTRUMENT_NAME         = "JOVIAN AURORAL DISTRIBUTIONS EXPERIMENT"           
INSTRUMENT_ID           = "JAD" /* JADE */                                    
DATA_SET_ID             = "JNO-J/SW-JAD-3-CALIBRATED-V1.0"                    
INSTRUMENT_HOST_NAME    = "JUNO"                                              
INSTRUMENT_HOST_ID      = "JNO"                                               
PRODUCT_ID              = "LUT_5_01_F_ENERGY"                                 
PRODUCT_TYPE            = "CALIBRATION"                                       
PRODUCT_VERSION_ID      = "01"                                                
PRODUCT_CREATION_TIME   = 2020-164T18:13:33 /* UTC 2020-06-12 */              
RECORD_TYPE             = STREAM                                              
                                                                              
FILE_RECORDS            = 64                                                  
MD5_CHECKSUM            = "e7dbe1be3afb8c3b67c540e342fbb0ab"                  
/* This is LUT 5.01, Time Period F.*/                                         
START_TIME              = 2020-147T00:00:00 /* UTC 2020-05-26 */              
STOP_TIME               = 2020-200T00:00:00 /* UTC 2020-07-18 */              
SPACECRAFT_CLOCK_START_COUNT = "643723524" /* = START_TIME */                 
SPACECRAFT_CLOCK_STOP_COUNT  = "648302730" /* = STOP_TIME  */                 
                                                                              
DESCRIPTION             = "Energy (and delta-E) Tables for LUT 5.01"          
NOTE                    = "                                                   
  Oscope Corrections for ION_T01_E used to calculate ION_T23_E                
  Tables *_T1_E and *_T2_E for E060, and E180 need additional analysis        
  ION_T01_DE values used for ION_T23_DE                                       
  *_T0_DE values used for *_T1_DE and *_T2_DE for E060, E180, E300            
                           "                                                  
                                                                              
^HEADER                 = ("LUT_5_01_F_ENERGY_V01.CSV",  1 ❮BYTES❯)           
OBJECT                  = HEADER                                              
  RECORDS                 = 1                                                 
  BYTES                   = 305                                               
  HEADER_TYPE             = TEXT                                              
END_OBJECT              = HEADER                                              
                                                                              
^SPREADSHEET            = ("LUT_5_01_F_ENERGY_V01.CSV",306 ❮BYTES❯)           
OBJECT                    = SPREADSHEET                                       
  ROWS                    = 64                                                
  ROW_BYTES               = 305                                               
  FIELDS                  = 23                                                
  FIELD_DELIMITER         = COMMA                                             
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 01                                                        
    NAME          = "STEP"                                                    
    BYTES         = 2                                                         
    DATA_TYPE     = ASCII_INTEGER                                             
    FORMAT        = "I2"                                                      
    DESCRIPTION   = "Voltage table step number."                              
    VALID_MINIMUM =  0                                                        
    VALID_MAXIMUM = 63                                                        
  END_OBJECT    = FIELD                                                       
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 02                                                        
    NAME          = "ION_T01_E"                                               
    BYTES         = 9                                                         
    DATA_TYPE     = ASCII_REAL                                                
    FORMAT        = "F9.3"                                                    
    DESCRIPTION   = "ION_T01_E Energy Table (eV/q)"                           
    VALID_MINIMUM =      0.0                                                  
    VALID_MAXIMUM = 100000.0                                                  
    UNIT          = "eV/q"                                                    
  END_OBJECT    = FIELD                                                       
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 03                                                        
    NAME          = "ION_T01_DE"                                              
    BYTES         = 11                                                        
    DATA_TYPE     = ASCII_REAL                                                
    FORMAT        = "F11.8"                                                   
    DESCRIPTION   = "ION_T01_DE: Delta-Energy values for ION_T01_E            
                     (percentage).  Multiply by ION_T01_E to get eV/q."       
    VALID_MINIMUM = 0.0 /* =   0% */                                          
    VALID_MAXIMUM = 1.0 /* = 100% */                                          
    UNIT          = "Percentage"                                              
  END_OBJECT    = FIELD                                                       
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 04                                                        
    NAME          = "ION_T23_E"                                               
    BYTES         = 9                                                         
    DATA_TYPE     = ASCII_REAL                                                
    FORMAT        = "F9.3"                                                    
    DESCRIPTION   = "ION_T23_E Energy Table (eV/q)"                           
    VALID_MINIMUM =      0.0                                                  
    VALID_MAXIMUM = 100000.0                                                  
    UNIT          = "eV/q"                                                    
  END_OBJECT    = FIELD                                                       
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 05                                                        
    NAME          = "ION_T23_DE"                                              
    BYTES         = 11                                                        
    DATA_TYPE     = ASCII_REAL                                                
    FORMAT        = "F11.8"                                                   
    DESCRIPTION   = "ION_T23_DE: Delta-Energy values for ION_T23_E            
                     (percentage).  Multiply by ION_T23_E to get eV/q."       
    VALID_MINIMUM = 0.0 /* =   0% */                                          
    VALID_MAXIMUM = 1.0 /* = 100% */                                          
    UNIT          = "Percentage"                                              
  END_OBJECT    = FIELD                                                       
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 06                                                        
    NAME          = "E060_T0_E"                                               
    BYTES         = 9                                                         
    DATA_TYPE     = ASCII_REAL                                                
    FORMAT        = "F9.3"                                                    
    DESCRIPTION   = "E060_T0_E Energy Table (eV/q)"                           
    VALID_MINIMUM =      0.0                                                  
    VALID_MAXIMUM = 100000.0                                                  
    UNIT          = "eV/q"                                                    
  END_OBJECT    = FIELD                                                       
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 07                                                        
    NAME          = "E060_T0_DE"                                              
    BYTES         = 11                                                        
    DATA_TYPE     = ASCII_REAL                                                
    FORMAT        = "F11.8"                                                   
    DESCRIPTION   = "E060_T0_DE: Delta-Energy values for E060_T0_E            
                     (percentage).  Multiply by E060_T0_E to get eV/q."       
    VALID_MINIMUM = 0.0 /* =   0% */                                          
    VALID_MAXIMUM = 1.0 /* = 100% */                                          
    UNIT          = "Percentage"                                              
  END_OBJECT    = FIELD                                                       
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 08                                                        
    NAME          = "E060_T1_E"                                               
    BYTES         = 9                                                         
    DATA_TYPE     = ASCII_REAL                                                
    FORMAT        = "F9.3"                                                    
    DESCRIPTION   = "E060_T1_E Energy Table (eV/q)"                           
    VALID_MINIMUM =      0.0                                                  
    VALID_MAXIMUM = 100000.0                                                  
    UNIT          = "eV/q"                                                    
  END_OBJECT    = FIELD                                                       
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 09                                                        
    NAME          = "E060_T1_DE"                                              
    BYTES         = 11                                                        
    DATA_TYPE     = ASCII_REAL                                                
    FORMAT        = "F11.8"                                                   
    DESCRIPTION   = "E060_T1_DE: Delta-Energy values for E060_T1_E            
                     (percentage).  Multiply by E060_T1_E to get eV/q."       
    VALID_MINIMUM = 0.0 /* =   0% */                                          
    VALID_MAXIMUM = 1.0 /* = 100% */                                          
    UNIT          = "Percentage"                                              
  END_OBJECT    = FIELD                                                       
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 10                                                        
    NAME          = "E060_T2_E"                                               
    BYTES         = 9                                                         
    DATA_TYPE     = ASCII_REAL                                                
    FORMAT        = "F9.3"                                                    
    DESCRIPTION   = "E060_T2_E Energy Table (eV/q)"                           
    VALID_MINIMUM =      0.0                                                  
    VALID_MAXIMUM = 100000.0                                                  
    UNIT          = "eV/q"                                                    
  END_OBJECT    = FIELD                                                       
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 11                                                        
    NAME          = "E060_T2_DE"                                              
    BYTES         = 11                                                        
    DATA_TYPE     = ASCII_REAL                                                
    FORMAT        = "F11.8"                                                   
    DESCRIPTION   = "E060_T2_DE: Delta-Energy values for E060_T2_E            
                     (percentage).  Multiply by E060_T2_E to get eV/q."       
    VALID_MINIMUM = 0.0 /* =   0% */                                          
    VALID_MAXIMUM = 1.0 /* = 100% */                                          
    UNIT          = "Percentage"                                              
  END_OBJECT    = FIELD                                                       
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 12                                                        
    NAME          = "E180_T0_E"                                               
    BYTES         = 9                                                         
    DATA_TYPE     = ASCII_REAL                                                
    FORMAT        = "F9.3"                                                    
    DESCRIPTION   = "E180_T0_E Energy Table (eV/q)"                           
    VALID_MINIMUM =      0.0                                                  
    VALID_MAXIMUM = 100000.0                                                  
    UNIT          = "eV/q"                                                    
  END_OBJECT    = FIELD                                                       
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 13                                                        
    NAME          = "E180_T0_DE"                                              
    BYTES         = 11                                                        
    DATA_TYPE     = ASCII_REAL                                                
    FORMAT        = "F11.8"                                                   
    DESCRIPTION   = "E180_T0_DE: Delta-Energy values for E180_T0_E            
                     (percentage).  Multiply by E180_T0_E to get eV/q."       
    VALID_MINIMUM = 0.0 /* =   0% */                                          
    VALID_MAXIMUM = 1.0 /* = 100% */                                          
    UNIT          = "Percentage"                                              
  END_OBJECT    = FIELD                                                       
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 14                                                        
    NAME          = "E180_T1_E"                                               
    BYTES         = 9                                                         
    DATA_TYPE     = ASCII_REAL                                                
    FORMAT        = "F9.3"                                                    
    DESCRIPTION   = "E180_T1_E Energy Table (eV/q)"                           
    VALID_MINIMUM =      0.0                                                  
    VALID_MAXIMUM = 100000.0                                                  
    UNIT          = "eV/q"                                                    
  END_OBJECT    = FIELD                                                       
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 15                                                        
    NAME          = "E180_T1_DE"                                              
    BYTES         = 11                                                        
    DATA_TYPE     = ASCII_REAL                                                
    FORMAT        = "F11.8"                                                   
    DESCRIPTION   = "E180_T1_DE: Delta-Energy values for E180_T1_E            
                     (percentage).  Multiply by E180_T1_E to get eV/q."       
    VALID_MINIMUM = 0.0 /* =   0% */                                          
    VALID_MAXIMUM = 1.0 /* = 100% */                                          
    UNIT          = "Percentage"                                              
  END_OBJECT    = FIELD                                                       
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 16                                                        
    NAME          = "E180_T2_E"                                               
    BYTES         = 9                                                         
    DATA_TYPE     = ASCII_REAL                                                
    FORMAT        = "F9.3"                                                    
    DESCRIPTION   = "E180_T2_E Energy Table (eV/q)"                           
    VALID_MINIMUM =      0.0                                                  
    VALID_MAXIMUM = 100000.0                                                  
    UNIT          = "eV/q"                                                    
  END_OBJECT    = FIELD                                                       
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 17                                                        
    NAME          = "E180_T2_DE"                                              
    BYTES         = 11                                                        
    DATA_TYPE     = ASCII_REAL                                                
    FORMAT        = "F11.8"                                                   
    DESCRIPTION   = "E180_T2_DE: Delta-Energy values for E180_T2_E            
                     (percentage).  Multiply by E180_T2_E to get eV/q."       
    VALID_MINIMUM = 0.0 /* =   0% */                                          
    VALID_MAXIMUM = 1.0 /* = 100% */                                          
    UNIT          = "Percentage"                                              
  END_OBJECT    = FIELD                                                       
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 18                                                        
    NAME          = "E300_T0_E"                                               
    BYTES         = 9                                                         
    DATA_TYPE     = ASCII_REAL                                                
    FORMAT        = "F9.3"                                                    
    DESCRIPTION   = "E300_T0_E Energy Table (eV/q)"                           
    VALID_MINIMUM =      0.0                                                  
    VALID_MAXIMUM = 100000.0                                                  
    UNIT          = "eV/q"                                                    
  END_OBJECT    = FIELD                                                       
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 19                                                        
    NAME          = "E300_T0_DE"                                              
    BYTES         = 11                                                        
    DATA_TYPE     = ASCII_REAL                                                
    FORMAT        = "F11.8"                                                   
    DESCRIPTION   = "E300_T0_DE: Delta-Energy values for E300_T0_E            
                     (percentage).  Multiply by E300_T0_E to get eV/q."       
    VALID_MINIMUM = 0.0 /* =   0% */                                          
    VALID_MAXIMUM = 1.0 /* = 100% */                                          
    UNIT          = "Percentage"                                              
  END_OBJECT    = FIELD                                                       
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 20                                                        
    NAME          = "E300_T1_E"                                               
    BYTES         = 9                                                         
    DATA_TYPE     = ASCII_REAL                                                
    FORMAT        = "F9.3"                                                    
    DESCRIPTION   = "E300_T1_E Energy Table (eV/q)"                           
    VALID_MINIMUM =      0.0                                                  
    VALID_MAXIMUM = 100000.0                                                  
    UNIT          = "eV/q"                                                    
  END_OBJECT    = FIELD                                                       
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 21                                                        
    NAME          = "E300_T1_DE"                                              
    BYTES         = 11                                                        
    DATA_TYPE     = ASCII_REAL                                                
    FORMAT        = "F11.8"                                                   
    DESCRIPTION   = "E300_T1_DE: Delta-Energy values for E300_T1_E            
                     (percentage).  Multiply by E300_T1_E to get eV/q."       
    VALID_MINIMUM = 0.0 /* =   0% */                                          
    VALID_MAXIMUM = 1.0 /* = 100% */                                          
    UNIT          = "Percentage"                                              
  END_OBJECT    = FIELD                                                       
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 22                                                        
    NAME          = "E300_T2_E"                                               
    BYTES         = 9                                                         
    DATA_TYPE     = ASCII_REAL                                                
    FORMAT        = "F9.3"                                                    
    DESCRIPTION   = "E300_T2_E Energy Table (eV/q)"                           
    VALID_MINIMUM =      0.0                                                  
    VALID_MAXIMUM = 100000.0                                                  
    UNIT          = "eV/q"                                                    
  END_OBJECT    = FIELD                                                       
                                                                              
  OBJECT        = FIELD                                                       
    FIELD_NUMBER  = 23                                                        
    NAME          = "E300_T2_DE"                                              
    BYTES         = 11                                                        
    DATA_TYPE     = ASCII_REAL                                                
    FORMAT        = "F11.8"                                                   
    DESCRIPTION   = "E300_T2_DE: Delta-Energy values for E300_T2_E            
                     (percentage).  Multiply by E300_T2_E to get eV/q."       
    VALID_MINIMUM = 0.0 /* =   0% */                                          
    VALID_MAXIMUM = 1.0 /* = 100% */                                          
    UNIT          = "Percentage"                                              
  END_OBJECT    = FIELD                                                       
                                                                              
END_OBJECT              = SPREADSHEET                                         
END