PDS_VERSION_ID = PDS3
DATA_SET_ID = "CO-S-MIMI-4-CHEMS-CALIB-V1.0"
PRODUCT_ID = "MIMI_CALIBRATION"
STANDARD_DATA_PRODUCT_ID = "MIMI_REF"
PRODUCT_TYPE = "DATA"
PRODUCT_VERSION_ID = "0011"
PRODUCT_CREATION_TIME = 2013-032T00:00:00.000
RECORD_TYPE = STREAM
INTERCHANGE_FORMAT = ASCII
FILE_RECORDS = 7123
START_TIME = 1997-288T00:00:00
STOP_TIME = 2030-001T00:00:00
NATIVE_START_TIME = "NULL"
NATIVE_STOP_TIME = "NULL"
SPACECRAFT_CLOCK_START_COUNT = "1/1255564906.086"
SPACECRAFT_CLOCK_STOP_COUNT = "1/2272153905.225"
INSTRUMENT_HOST_NAME = "CASSINI ORBITER"
INSTRUMENT_HOST_ID = "CO"
MISSION_PHASE_NAME = "N/A"
ORBIT_NUMBER = "N/A"
TARGET_NAME = "N/A"
INSTRUMENT_NAME = "MAGNETOSPHERIC IMAGING INSTRUMENT"
INSTRUMENT_ID = "MIMI"
DESCRIPTION = "
Calibration information for each of the Sensors of the MIMI Instrument."
^HEADER = ("MIMI_CALIBRATION_0011.CSV", 1 ❮BYTES❯)
^SPREADSHEET = ("MIMI_CALIBRATION_0011.CSV", 147 ❮BYTES❯)
OBJECT = HEADER
RECORDS = 1
BYTES = 146
HEADER_TYPE = SPREADSHEET
DESCRIPTION = "
This file contains a single row of column headings (text strings enclosed
within double quotes) separated by commas."
END_OBJECT = HEADER
OBJECT = SPREADSHEET
ROWS = 7122
FIELDS = 15
ROW_BYTES = 328
FIELD_DELIMITER = COMMA
OBJECT = FIELD
NAME = "PURPOSE"
FIELD_NUMBER = 1
DATA_TYPE = CHARACTER
BYTES = 32
DESCRIPTION = "
The PURPOSE field identifies the purpose or function of the data
contained in the current row. Valid entries include:
E/NUC_B - The B coefficient for the CHEMS instrument - see instrument
paper KRIMIGISETAL2004
EFFICIENCY - the efficiency of the particular channel or detector
ENERGY - the energy passband for the particular channel or detector
ENERGY/CHARGE - the energy per charge passband for the particular
channel or detector
FOV - the Field of View for the particular detector
GEOM_FACTOR - the geometrical factor for the particular channel or
detector
MASS - the mass passband for the particular channel or detector
MASS/CHARGE - the mass per charge passband for the particular channel
or detector."
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Data_Type"
FIELD_NUMBER = 2
UNIT = "N/A"
DATA_TYPE = CHARACTER
BYTES = 3
DESCRIPTION = "
The data type (or data source)."
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Sensor"
FIELD_NUMBER = 3
UNIT = "N/A"
DATA_TYPE = CHARACTER
BYTES = 5
DESCRIPTION = "
The sensor for which the calibration data pertains."
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Channel"
FIELD_NUMBER = 4
UNIT = "N/A"
DATA_TYPE = CHARACTER
BYTES = 9
DESCRIPTION = "
The Channel for which the calibration data pertains."
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Channel_Index"
FIELD_NUMBER = 5
DATA_TYPE = ASCII_INTEGER
BYTES = 1
VALID_MINIMUM = 0
VALID_MAXIMUM = 63
DESCRIPTION = "
The channel index for which the calibration data pertains. i.e.
channel = 'A' index = 5 is the A5 channel."
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Particle"
FIELD_NUMBER = 6
UNIT = "N/A"
DATA_TYPE = CHARACTER
BYTES = 4
DESCRIPTION = "
The particle for which the calibration data pertains.
Multiple particle entries are possible. The first entry for a
particular channel or detector is the primary particle expected during
the mission although this is highly dependent upon the environment. A
particle entry of ALL indicates that the channel or detector is
responsive to all particles."
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Start_Year"
FIELD_NUMBER = 7
DATA_TYPE = ASCII_INTEGER
BYTES = 4
VALID_MINIMUM = 1997
VALID_MAXIMUM = 2030
DESCRIPTION = "
The starting year for which the calibration information pertains."
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Start_DDOY"
FIELD_NUMBER = 8
DATA_TYPE = ASCII_REAL
BYTES = 12
VALID_MINIMUM = 1.000
VALID_MAXIMUM = 365.99999999
DESCRIPTION = "
The starting decimal day of year for which the calibration information
pertains."
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "End_Year"
FIELD_NUMBER = 9
DATA_TYPE = ASCII_INTEGER
BYTES = 4
VALID_MINIMUM = 1997
VALID_MAXIMUM = 2030
DESCRIPTION = "
The ending year for which the calibration information pertains."
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "End_DDOY"
FIELD_NUMBER = 10
DATA_TYPE = ASCII_REAL
BYTES = 12
VALID_MINIMUM = 1.000
VALID_MAXIMUM = 365.99999999
DESCRIPTION = "
The ending decimal day of year (exclusive) for which the calibration
information pertains."
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Units"
FIELD_NUMBER = 11
DATA_TYPE = CHARACTER
BYTES = 7
DESCRIPTION = "
The units of the calibration data."
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Low"
FIELD_NUMBER = 12
DATA_TYPE = ASCII_REAL
BYTES = 12
VALID_MINIMUM = 0.000
VALID_MAXIMUM = 999999.00000
DESCRIPTION = "
The low passband value (inclusive) for those calibration data values
that have high and low values. For those calibration data values that
are single valued then this field is left empty."
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Hi"
FIELD_NUMBER = 13
DATA_TYPE = ASCII_REAL
BYTES = 13
VALID_MINIMUM = 0.000
VALID_MAXIMUM = 9999999.00000
DESCRIPTION = "
The high passband value (inclusive) for those calibration data values
that have high and low values. For those calibration data values that
are single valued or are open ended then this field is left empty."
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Delta"
FIELD_NUMBER = 14
DATA_TYPE = ASCII_REAL
BYTES = 12
VALID_MINIMUM = 0.000
VALID_MAXIMUM = 999999.00000
DESCRIPTION = "
The delta of the passband which is usually hi - low but can be other
values based upon other specific information available to the MIMI team.
In general, the Delta field should be used for passband calculations
instead of the difference between hi and low. For those calibration
data values that are single values or are open ended (i.e. integral
channels) then this field is left empty."
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Midpoint_Value"
FIELD_NUMBER = 15
DATA_TYPE = ASCII_REAL
BYTES = 12
VALID_MINIMUM = 0.0000
VALID_MAXIMUM = 999999.00000
DESCRIPTION = "
Either the midpoint of the passband or the value of the single valued
calibration data. In general, the Midpoint_Value is calculated as
(hi + low)/2 but can be other values based upon other specific
information available to the MIMI team. For those calibration data
values that are open ended (i.e. integral) then this field is left
empty."
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Source"
FIELD_NUMBER = 16
DATA_TYPE = CHARACTER
BYTES = 6
DESCRIPTION = "
The source field identifies the primary source of the information for
the particle data. The options are UMD = University of Maryland
APL = Applied Physics Laboratory, and TEAM = an agreed upon number by
the members of the team."
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Comment"
FIELD_NUMBER = 17
DATA_TYPE = CHARACTER
BYTES = 104
DESCRIPTION = "
This field contains any comments that are deemed relevant by the team."
END_OBJECT = FIELD
END_OBJECT = SPREADSHEET