Download this file

PDS_VERSION_ID            = PDS3

RECORD_TYPE               = STREAM
FILE_RECORDS              = 480

START_TIME                = 2014-060T00:00
STOP_TIME                 = 2014-080T00:00

SPACECRAFT_CLOCK_START_COUNT = "1/1772326671:78"
SPACECRAFT_CLOCK_STOP_COUNT = "1/1774054682:73"

^HEADER                   = ("CPHAFLX0_T1_WP_2014060_2014080_02.CSV", 1 ❮BYTES❯)
^SPREADSHEET              = ("CPHAFLX0_T1_WP_2014060_2014080_02.CSV",
    1758 ❮BYTES❯)
MD5_CHECKSUM              = "9efe88d72f5e16ba17d6eb85ab857daa"

PRODUCT_TYPE              = "DATA"
DATA_SET_ID               = "CO-S-MIMI-4-CHEMS-CALIB-V1.0"
PRODUCT_ID                = CPHAFLX0_T1_WP_2014060_2014080
STANDARD_DATA_PRODUCT_ID  = CHEMS_PHAFLUXAV_WP
PRODUCT_VERSION_ID        = "02"
INSTRUMENT_HOST_NAME      = "CASSINI ORBITER"
INSTRUMENT_HOST_ID        = CO
TARGET_NAME               = SATURN
INSTRUMENT_NAME           = "MAGNETOSPHERIC IMAGING INSTRUMENT"
INSTRUMENT_ID             = MIMI
PRODUCT_CREATION_TIME     = 2014-259T13:53:16
DESCRIPTION               = "CHEMS 1-hour average PHA flux values in 20
    day files

    Arrangement of these files is made to match other PDS data files for MIMI.
    Not all elements in the standard format are filled out in these CHEMS
    files. For example, the header rows that describe the data have not been
    filled out, but are just empty (this includes valid_min, valid_max, min,
    max, mean, stdev)."

OBJECT                    = HEADER
  RECORDS                 = 1
  BYTES                   = 1757
  HEADER_TYPE             = SPREADSHEET
  DESCRIPTION             = "column names for the fields; note that the
    spacecraft position is in the SZS frame"
END_OBJECT                = HEADER


OBJECT                    = SPREADSHEET
  FIELDS                  = 84
  FIELD_DELIMITER         = COMMA
  ROW_BYTES               = 766
  ROWS                    = 480

  OBJECT                  = FIELD
    NAME                  = "Purpose"
    DATA_TYPE             = "CHARACTER"
    FIELD_NUMBER          = 1
    BYTES                 = 3
    DESCRIPTION           = "indicates that this row contains science
    data"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "UTC"
    DATA_TYPE             = "TIME"
    FIELD_NUMBER          = 2
    BYTES                 = 21
    DESCRIPTION           = "midpoint time of the averaging interval as a
    UTC string in ISO 8601 format"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "SCLOCK"
    DATA_TYPE             = "TIME"
    FIELD_NUMBER          = 3
    BYTES                 = 16
    DESCRIPTION           = "midpoint time of the averaging interval as a
    spacecraft clock string; SCLOCK values are recorded as P/NNNNNNNNNN.FFF
    where P is the partition number, NNNNNNNNNN is roughly the number of
    seconds since the start of the partition, and FFF is the number of ticks.
    Each tick is roughly 1/256 of a second."
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Start_Ephemeris_s"
    UNIT                  = "SECONDS"
    DATA_TYPE             = "TIME"
    FIELD_NUMBER          = 4
    BYTES                 = 22
    DESCRIPTION           = "start time of the averaging interval in
    ephemeris time (TDB seconds past the J2000 epoch)"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "End_Ephemeris_s"
    UNIT                  = "SECONDS"
    DATA_TYPE             = "TIME"
    FIELD_NUMBER          = 5
    BYTES                 = 22
    DESCRIPTION           = "end time of the averaging interval in
    ephemeris time (TDB seconds past the J2000 epoch)"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Spin_Counter"
    UNIT                  = "N/A"
    DATA_TYPE             = "N/A"
    FIELD_NUMBER          = 6
    BYTES                 = 3
    DESCRIPTION           = "unused field in this file"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Sector"
    UNIT                  = "N/A"
    DATA_TYPE             = "N/A"
    FIELD_NUMBER          = 7
    BYTES                 = 3
    DESCRIPTION           = "unused field in this file"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Start_Sector_Sclock_major"
    UNIT                  = "N/A"
    DATA_TYPE             = "N/A"
    FIELD_NUMBER          = 8
    BYTES                 = 3
    DESCRIPTION           = "unused field in this file"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Subsector"
    UNIT                  = "N/A"
    DATA_TYPE             = "N/A"
    FIELD_NUMBER          = 9
    BYTES                 = 3
    DESCRIPTION           = "unused field in this file"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Microsectors_Covered"
    UNIT                  = "N/A"
    DATA_TYPE             = "N/A"
    FIELD_NUMBER          = 10
    BYTES                 = 3
    DESCRIPTION           = "unused field in this file"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Spin_Period_s"
    UNIT                  = "N/A"
    DATA_TYPE             = "N/A"
    FIELD_NUMBER          = 11
    BYTES                 = 3
    DESCRIPTION           = "unused field in this file"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Staring"
    UNIT                  = "N/A"
    DATA_TYPE             = "N/A"
    FIELD_NUMBER          = 12
    BYTES                 = 3
    DESCRIPTION           = "unused field in this file"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Sensor_Bitrate"
    UNIT                  = "N/A"
    DATA_TYPE             = "N/A"
    FIELD_NUMBER          = 13
    BYTES                 = 3
    DESCRIPTION           = "unused field in this file"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Start"
    UNIT                  = "MINUTES"
    DATA_TYPE             = "TIME"
    FIELD_NUMBER          = 14
    BYTES                 = 14
    DESCRIPTION           = "start time of hour-long average"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Stop"
    UNIT                  = "MINUTES"
    DATA_TYPE             = "TIME"
    FIELD_NUMBER          = 15
    BYTES                 = 14
    DESCRIPTION           = "end time of hour-long average"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Year"
    UNIT                  = "YEARS"
    DATA_TYPE             = "TIME"
    FIELD_NUMBER          = 16
    BYTES                 = 4
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Ave_doy"
    UNIT                  = "DAYS"
    DATA_TYPE             = "TIME"
    FIELD_NUMBER          = 17
    BYTES                 = 8
    DESCRIPTION           = "midpoint of the hour-long averaging interval
    expressed as a fractional day of year"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Radial_Distance"
    UNIT                  = "RS"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 18
    BYTES                 = 8
    DESCRIPTION           = "position of Cassini at midpoint of interval
    in Saturn radii, where 1 RS = 60268 km"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Latitude"
    UNIT                  = "DEGREES"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 19
    BYTES                 = 7
    DESCRIPTION           = "latitude of Cassini at midpoint of
    measurement in the SZS (Saturn Equatorial System) frame"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Local_Time"
    UNIT                  = "HOURS"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 20
    BYTES                 = 6
    DESCRIPTION           = "local time of Cassini at the midpoint of the
    measurement given in hours and in the SZS system"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_0"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 21
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 0; energy
    bandwidth for this step is 2.77 to 2.85 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_0_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 22
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_1"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 23
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 1; energy
    bandwidth for this step is 3.24 to 3.34 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_1_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 24
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_2"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 25
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 2; energy
    bandwidth for this step is 3.72 to 3.84 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_2_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 26
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_3"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 27
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 3; energy
    bandwidth for this step is 4.33 to 4.47 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_3_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 28
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_4"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 29
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 4; energy
    bandwidth for this step is 4.97 to 5.13 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_4_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 30
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_5"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 31
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 5; energy
    bandwidth for this step is 5.77 to 5.95 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_5_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 32
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_6"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 33
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 6; energy
    bandwidth for this step is 6.65 to 6.85 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_6_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 34
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_7"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 35
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 7; energy
    bandwidth for this step is 7.69 to 7.93 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_7_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 36
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_8"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 37
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 8; energy
    bandwidth for this step is 8.79 to 9.05 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_8_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 38
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_9"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 39
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 9; energy
    bandwidth for this step is 10.15 to 10.45 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_9_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 40
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_10"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 41
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 10; energy
    bandwidth for this step is 11.62 to 11.98 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_10_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 42
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_11"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 43
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 11; energy
    bandwidth for this step is 13.40 to 13.80 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_11_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 44
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_12"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 45
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 12; energy
    bandwidth for this step is 15.46 to 15.94 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_12_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 46
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_13"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 47
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 13; energy
    bandwidth for this step is 17.83 to 18.37 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_13_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 48
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_14"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 49
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 14; energy
    bandwidth for this step is 20.49 to 21.11 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_14_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 50
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_15"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 51
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 15; energy
    bandwidth for this step is 23.54 to 24.26 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_15_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 52
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_16"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 53
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 16; energy
    bandwidth for this step is 26.99 to 27.81 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_16_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 54
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_17"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 55
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 17; energy
    bandwidth for this step is 31.03 to 31.97 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_17_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 56
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_18"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 57
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 18; energy
    bandwidth for this step is 35.66 to 36.74 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_18_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 58
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_19"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 59
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 19; energy
    bandwidth for this step is 40.98 to 42.22 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_19_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 60
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_20"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 61
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 20; energy
    bandwidth for this step is 47.08 to 48.52 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_20_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 62
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_21"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 63
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 21; energy
    bandwidth for this step is 54.08 to 55.72 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_21_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 64
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_22"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 65
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 22; energy
    bandwidth for this step is 62.25 to 64.15 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_22_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 66
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_23"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 67
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 23; energy
    bandwidth for this step is 71.51 to 73.69 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_23_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 68
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_24"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 69
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 24; energy
    bandwidth for this step is 82.15 to 84.65 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_24_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 70
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_25"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 71
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 25; energy
    bandwidth for this step is 94.46 to 97.34 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_25_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 72
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_26"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 73
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 26; energy
    bandwidth for this step is 108.45 to 111.75 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_26_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 74
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_27"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 75
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 27; energy
    bandwidth for this step is 124.70 to 128.50 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_27_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 76
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_28"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 77
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 28; energy
    bandwidth for this step is 143.12 to 147.48 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_28_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 78
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_29"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 79
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 29; energy
    bandwidth for this step is 164.40 to 169.40 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_29_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 80
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_30"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 81
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 30; energy
    bandwidth for this step is 188.73 to 194.47 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_30_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 82
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_31"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 83
    BYTES                 = 10
    DESCRIPTION           = "intensity of W+ ions at DPPS step 31; energy
    bandwidth for this step is 216.90 to 223.50 keV/Q"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "W+Flux_31_sigma"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 84
    BYTES                 = 10
    DESCRIPTION           = "uncertainty in particle intensity"
  END_OBJECT              = FIELD

END_OBJECT                = SPREADSHEET

END