PDS_VERSION_ID = PDS3
RECORD_TYPE = STREAM
FILE_RECORDS = 480
START_TIME = 2013-100T00:00
STOP_TIME = 2013-120T00:00
SPACECRAFT_CLOCK_START_COUNT = "1/1744246492:227"
SPACECRAFT_CLOCK_STOP_COUNT = "1/1745974503:224"
^HEADER = ("CPHAFLX0_T1_HEPP_2013100_2013120_02.CSV", 1 ❮BYTES❯)
^SPREADSHEET = ("CPHAFLX0_T1_HEPP_2013100_2013120_02.CSV",
1886 ❮BYTES❯)
MD5_CHECKSUM = "2768a459d71fe0e3f15398ca4f9b23c3"
PRODUCT_TYPE = "DATA"
DATA_SET_ID = "CO-S-MIMI-4-CHEMS-CALIB-V1.0"
PRODUCT_ID = CPHAFLX0_T1_HEPP_2013100_2013120
STANDARD_DATA_PRODUCT_ID = CHEMS_PHAFLUXAV_HEPP
PRODUCT_VERSION_ID = "02"
INSTRUMENT_HOST_NAME = "CASSINI ORBITER"
INSTRUMENT_HOST_ID = CO
TARGET_NAME = SATURN
INSTRUMENT_NAME = "MAGNETOSPHERIC IMAGING INSTRUMENT"
INSTRUMENT_ID = MIMI
PRODUCT_CREATION_TIME = 2014-002T12:06:40
DESCRIPTION = "CHEMS 1-hour average PHA flux values in 20
day files
Arrangement of these files is made to match other PDS data files for MIMI.
Not all elements in the standard format are filled out in these CHEMS
files. For example, the header rows that describe the data have not been
filled out, but are just empty (this includes valid_min, valid_max, min,
max, mean, stdev)."
OBJECT = HEADER
RECORDS = 1
BYTES = 1885
HEADER_TYPE = SPREADSHEET
DESCRIPTION = "column names for the fields; note that the
spacecraft position is in the SZS frame"
END_OBJECT = HEADER
OBJECT = SPREADSHEET
FIELDS = 84
FIELD_DELIMITER = COMMA
ROW_BYTES = 751
ROWS = 480
OBJECT = FIELD
NAME = "Purpose"
DATA_TYPE = "CHARACTER"
FIELD_NUMBER = 1
BYTES = 3
DESCRIPTION = "indicates that this row contains science
data"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "UTC"
DATA_TYPE = "TIME"
FIELD_NUMBER = 2
BYTES = 21
DESCRIPTION = "midpoint time of the averaging interval as a
UTC string in ISO 8601 format"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "SCLOCK"
DATA_TYPE = "TIME"
FIELD_NUMBER = 3
BYTES = 16
DESCRIPTION = "midpoint time of the averaging interval as a
spacecraft clock string; SCLOCK values are recorded as P/NNNNNNNNNN.FFF
where P is the partition number, NNNNNNNNNN is roughly the number of
seconds since the start of the partition, and FFF is the number of ticks.
Each tick is roughly 1/256 of a second."
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Start_Ephemeris_s"
UNIT = "SECONDS"
DATA_TYPE = "TIME"
FIELD_NUMBER = 4
BYTES = 22
DESCRIPTION = "start time of the averaging interval in
ephemeris time (TDB seconds past the J2000 epoch)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "End_Ephemeris_s"
UNIT = "SECONDS"
DATA_TYPE = "TIME"
FIELD_NUMBER = 5
BYTES = 22
DESCRIPTION = "end time of the averaging interval in
ephemeris time (TDB seconds past the J2000 epoch)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Spin_Counter"
UNIT = "N/A"
DATA_TYPE = "N/A"
FIELD_NUMBER = 6
BYTES = 3
DESCRIPTION = "unused field in this file"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Sector"
UNIT = "N/A"
DATA_TYPE = "N/A"
FIELD_NUMBER = 7
BYTES = 3
DESCRIPTION = "unused field in this file"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Start_Sector_Sclock_major"
UNIT = "N/A"
DATA_TYPE = "N/A"
FIELD_NUMBER = 8
BYTES = 3
DESCRIPTION = "unused field in this file"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Subsector"
UNIT = "N/A"
DATA_TYPE = "N/A"
FIELD_NUMBER = 9
BYTES = 3
DESCRIPTION = "unused field in this file"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Microsectors_Covered"
UNIT = "N/A"
DATA_TYPE = "N/A"
FIELD_NUMBER = 10
BYTES = 3
DESCRIPTION = "unused field in this file"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Spin_Period_s"
UNIT = "N/A"
DATA_TYPE = "N/A"
FIELD_NUMBER = 11
BYTES = 3
DESCRIPTION = "unused field in this file"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Staring"
UNIT = "N/A"
DATA_TYPE = "N/A"
FIELD_NUMBER = 12
BYTES = 3
DESCRIPTION = "unused field in this file"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Sensor_Bitrate"
UNIT = "N/A"
DATA_TYPE = "N/A"
FIELD_NUMBER = 13
BYTES = 3
DESCRIPTION = "unused field in this file"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Start"
UNIT = "MINUTES"
DATA_TYPE = "TIME"
FIELD_NUMBER = 14
BYTES = 14
DESCRIPTION = "start time of hour-long average"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Stop"
UNIT = "MINUTES"
DATA_TYPE = "TIME"
FIELD_NUMBER = 15
BYTES = 14
DESCRIPTION = "end time of hour-long average"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Year"
UNIT = "YEARS"
DATA_TYPE = "TIME"
FIELD_NUMBER = 16
BYTES = 4
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Ave_doy"
UNIT = "DAYS"
DATA_TYPE = "TIME"
FIELD_NUMBER = 17
BYTES = 8
DESCRIPTION = "midpoint of the hour-long averaging interval
expressed as a fractional day of year"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Radial_Distance"
UNIT = "RS"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 18
BYTES = 8
DESCRIPTION = "position of Cassini at midpoint of interval
in Saturn radii, where 1 RS = 60268 km"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Latitude"
UNIT = "DEGREES"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 19
BYTES = 7
DESCRIPTION = "latitude of Cassini at midpoint of
measurement in the SZS (Saturn Equatorial System) frame"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Local_Time"
UNIT = "HOURS"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 20
BYTES = 6
DESCRIPTION = "local time of Cassini at the midpoint of the
measurement given in hours and in the SZS system"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_0"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 21
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 0; energy
bandwidth for this step is 2.77 to 2.85 keV/Q (5.54 to 5.70 as just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_0_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 22
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_1"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 23
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 1; energy
bandwidth for this step is 3.24 to 3.34 keV/Q (6.48 to 6.68 as just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_1_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 24
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_2"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 25
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 2; energy
bandwidth for this step is 3.72 to 3.84 keV/Q (7.45 to 7.67 as just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_2_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 26
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_3"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 27
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 3; energy
bandwidth for this step is 4.33 to 4.47 keV/Q (8.67 to 8.93 as just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_3_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 28
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_4"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 29
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 4; energy
bandwidth for this step is 4.97 to 5.13 keV/Q (9.95 to 10.25 as just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_4_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 30
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_5"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 31
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 5; energy
bandwidth for this step is 5.77 to 5.95 keV/Q (11.54 to 11.90 as just
keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_5_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 32
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_6"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 33
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 6; energy
bandwidth for this step is 6.65 to 6.85 keV/Q (13.30 to 13.70 as just
keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_6_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 34
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_7"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 35
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 7; energy
bandwidth for this step is 7.69 to 7.93 keV/Q (15.39 to 15.85 as just
keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_7_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 36
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_8"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 37
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 8; energy
bandwidth for this step is 8.79 to 9.05 keV/Q (17.57 to 18.11 as just
keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_8_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 38
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_9"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 39
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 9; energy
bandwidth for this step is 10.15 to 10.45 keV/Q (20.29 to 20.91 as just
keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_9_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 40
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_10"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 41
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 10;
energy bandwidth for this step is 11.62 to 11.98 keV/Q (23.25 to 23.95 as
just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_10_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 42
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_11"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 43
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 11;
energy bandwidth for this step is 13.40 to 13.80 keV/Q (26.79 to 27.61 as
just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_11_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 44
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_12"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 45
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 12;
energy bandwidth for this step is 15.46 to 15.94 keV/Q (30.93 to 31.87 as
just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_12_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 46
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_13"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 47
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 13;
energy bandwidth for this step is 17.83 to 18.37 keV/Q (35.66 to 36.74 as
just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_13_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 48
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_14"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 49
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 14;
energy bandwidth for this step is 20.49 to 21.11 keV/Q (40.98 to 42.22 as
just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_14_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 50
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_15"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 51
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 15;
energy bandwidth for this step is 23.54 to 24.26 keV/Q (47.08 to 48.52 as
just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_15_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 52
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_16"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 53
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 16;
energy bandwidth for this step is 26.99 to 27.81 keV/Q (53.98 to 55.62 as
just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_16_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 54
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_17"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 55
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 17;
energy bandwidth for this step is 31.03 to 31.97 keV/Q (62.06 to 63.94 as
just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_17_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 56
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_18"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 57
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 18;
energy bandwidth for this step is 35.66 to 36.74 keV/Q (71.31 to 73.49 as
just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_18_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 58
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_19"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 59
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 19;
energy bandwidth for this step is 40.98 to 42.22 keV/Q (81.95 to 84.45 as
just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_19_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 60
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_20"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 61
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 20;
energy bandwidth for this step is 47.08 to 48.52 keV/Q (94.17 to 97.03 as
just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_20_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 62
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_21"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 63
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 21;
energy bandwidth for this step is 54.08 to 55.72 keV/Q (108.15 to 111.45
as just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_21_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 64
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_22"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 65
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 22;
energy bandwidth for this step is 62.25 to 64.15 keV/Q (124.50 to 128.30
as just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_22_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 66
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_23"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 67
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 23;
energy bandwidth for this step is 71.51 to 73.69 keV/Q (143.02 to 147.38
as just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_23_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 68
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_24"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 69
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 24;
energy bandwidth for this step is 82.15 to 84.65 keV/Q (164.30 to 169.30
as just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_24_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 70
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_25"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 71
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 25;
energy bandwidth for this step is 94.46 to 97.34 keV/Q (188.92 to 194.68
as just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_25_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 72
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_26"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 73
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 26;
energy bandwidth for this step is 108.45 to 111.75 keV/Q (216.90 to 223.50
as just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_26_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 74
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_27"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 75
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 27;
energy bandwidth for this step is 124.70 to 128.50 keV/Q (249.40 to 257.00
as just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_27_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 76
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_28"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 77
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 28;
energy bandwidth for this step is 143.12 to 147.48 keV/Q (286.24 to 294.96
as just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_28_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 78
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_29"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 79
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 29;
energy bandwidth for this step is 164.40 to 169.40 keV/Q (328.79 to 338.81
as just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_29_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 80
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_30"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 81
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 30;
energy bandwidth for this step is 188.73 to 194.47 keV/Q (377.45 to 388.95
as just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_30_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 82
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_31"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 83
BYTES = 10
DESCRIPTION = "intensity of He++ ions at DPPS step 31;
energy bandwidth for this step is 216.90 to 223.50 keV/Q (433.79 to 447.01
as just keV)"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "He++Flux_31_sigma"
UNIT = "counts/sec/ster/cm^2/keV"
DATA_TYPE = "ASCII_REAL"
FIELD_NUMBER = 84
BYTES = 10
DESCRIPTION = "uncertainty in particle intensity"
END_OBJECT = FIELD
END_OBJECT = SPREADSHEET
END
|