Download this file

PDS_VERSION_ID        = PDS3                                                 
DATA_SET_ID           = "CO-E/SW/J/S-MAG-2-REDR-RAW-DATA-V1.0"               
RECORD_TYPE           = STREAM                                               
OBJECT                = TEXT                                                 
  PUBLICATION_DATE    = 2015-07-01                                           
  NOTE                  = "This file describes known errors or               
                           deficiencies in this archive volume."             
END_OBJECT            = TEXT                                                 
END                                                                          
                                                                             
Users are encouraged to provide comments back to the PPI Node of the PDS     
if errors or omissions are found either in data or in documentation.         
Please send comments by e-mail or U.S. mail to the PPI Node PDS Operator:    
                                                                             
  Email             pds_operator@igpp.ucla.edu                               
                                                                             
  Telephone         (310) 206-6073                                           
                                                                             
  U.S. Mail         PDS Operator                                             
                    c/o Dr. Raymond Walker                                   
                    3845 Slichter Hall                                       
                    UCLA - IGPP                                              
                    Los Angeles, CA 90095-1567                               
                                                                             
=============================================================================
This volume was originally online as the COMAG_0XXX (name changed to         
COMAG_0001 on 2013-08-20) volume.  The following is the original errata from 
that volume:                                                                 
                                                                             
Cumulative errata for this volume:                                           
                                                                             
Logical                                                                      
Volume     Error/Variance Description                                        
                                                                             
------------------------------------------------------------------------     
                                                                             
1) New Static Standard Values                                                
                                                                             
     PRODUCT_TYPE    {DATA, GEOMETRY, CALIBRATION, DOCUMENT,                 
                     CATALOG, SOFTWARE ANCILLARY, BROWSE}                    
                                                                             
     HEADER object with HEADER_TYPE = TEXT.                                  
                                                                             
     Software change requests have been submitted to the PDS to adopt these  
     changes to the PDS standards but they have not yet been accepted.       
                                                                             
                                                                             
2) Other non-standard practices                                              
                                                                             
     The PDS standards do not specify where to store the required MD5        
     checksum file for a volume.  We have placed it in the root dircetory    
     of the volume with the file name "CHECKSUMS.TXT".  This may be          
     considered invalid by some verifiers.                                   
                                                                             
     File names are typically longer than 8.3                                
                                                                             
     Directory names can be longer than 8 characters.                        
                                                                             
     Binary data files use the extension ".FFD" rather than the standard     
     ".DAT" extension. In addition, data files are described by a second,    
     non-PDS, detached header (.FFH) which is not common PDS practice. These 
     "flatfile headers" allow the data to be read and analyzed with a variety
     or software packages designed for working with IGPP flatfiles.          
     The time tag in the data files is provided in a non-standard form of    
     the spacecraft clock (SCLK). The Cassini SCLK is usually represented as 
     two numbers separated by full stop (.). The first number is the number  
     of "seconds" since 1958 and the second number represents the number of  
     1/256 of a second between seconds. The MAG data records need to be      
     timed to at least millisecond accuracy. Therefore, the second number in 
     the spacecraft clock has been converted into milliseconds. In order to  
     reproduce true spacecraft clock, multiply the second part of the SCLK   
     by 256/1000  and round to the nearest integer.                          
                                                                             
     PDS requires that each archive document be provided in an ASCII or      
     clean HTML (easily human readable) format. At the time the first disks  
     of this volume series were produced some of the documents on this volume
     had not been signed and were subject to change. The clean HTML version  
     the documents was not generated until volume COMA_0001. All subsequent  
     volumes have the required, "clean" HTML version of the documents.       
                                                                             
     All volumes in the volume series should have calibration tables in the  
     CALIB directory and software to read the data and calibrations files    
     and output calibrated data. The "test volume" does not contain these    
     files.                                                                  
                                                                             
     PPI has created copies of the PDS catalog files in the EXTRAS/CATALOG   
     directory with a ".TXT" extension. While this makes the files accessible
     to users with the Windows operating system, it is not a standard        
     PDS practice.                                                           
                                                                             
     In order for PPI to be able to track all of the files associated with a 
     data set (data, documents, software, etc.) and to be able to retrieve   
     them on-demand through our web pages, PPI must include keywords in      
     labels that some might find questionable. In particular, we associate   
     the same start/stop time, targets, mission phases, etc. with a document 
     or piece of software that are used in the data set. Without these       
     keywords, queries for Cassini MAG data between times A and B would      
     not return the documents or software associated with the data.          
                                                                             
3) Known problems and the volumes they affect                                
                                                                             
Volume      Error Description                                                
----------  ---------------------------------------------------------------   
COMAG_0001  The data contain persistent noise signals at 0.2, 8, 16 Hz, and   
            associated harmonics.  This noise was not observed during ground  
            testing of the instruments and is anticipated to be interference  
            arising from the spacecraft.  Removal of these signals is at the  
            user's discretion.                                                
                                                                              
COMAG_0001  The volume previously distributed on-line as COMAG_0XXX has been  
            renamed COMAG_0001. The data products contained on the volume     
            have not changed.                                                 
                                                                              
COMAG_0001  The software previously provided in the /SOFTWARE directory of    
            this volume have now been moved to /DOCUMENT/SOFTWARE. These      
            files (including both source code and MS-DOS executables) are     
            provided as documentation. PDS-PPI does not guarantee that they   
            will compile and run correctly on a given computer system.