PDS_VERSION_ID = PDS3
DATA_SET_ID = {"CO-E/J/S/SW-MIMI-2-INCA-UNCALIB-V1.1",
"CO-S-MIMI-4-INCA-CALIB-V1.0"}
PRODUCT_ID = "MIMI_INCA_OUTCAL_2005_01"
STANDARD_DATA_PRODUCT_ID = "MIMI_DATAGAPS"
PRODUCT_TYPE = "ANCILLARY"
PRODUCT_CREATION_TIME = 2018-124T15:08:05
RECORD_TYPE = STREAM
INTERCHANGE_FORMAT = ASCII
FILE_RECORDS = 138
START_TIME = 2005-001T00:00:00.000
STOP_TIME = 2005-365T23:59:59.999
NATIVE_START_TIME = "157809664.183"
NATIVE_STOP_TIME = "189345664.182"
SPACECRAFT_CLOCK_START_COUNT = "1/1483230358.000"
SPACECRAFT_CLOCK_STOP_COUNT = "1/1514766560.000"
INSTRUMENT_HOST_NAME = "CASSINI ORBITER"
INSTRUMENT_HOST_ID = "CO"
MISSION_PHASE_NAME = "TOUR"
TARGET_NAME = "SATURN"
INSTRUMENT_NAME = "MAGNETOSPHERIC IMAGING INSTRUMENT"
INSTRUMENT_ID = "MIMI"
DESCRIPTION = "The INCA out of calibration files are comma
delimited files, containing the times that the INCA images were considered
out of calibration. The time ranges in the files have been further divided
into periods to indicate whether the period was a planned (1) or
unplanned (2) out of calibration event but all of these time periods should
be considered to be out of calibration.
(Unplanned) Mode 2 INCA high voltage start GT 1500 AND LT 1855 OR
INCA high voltage stop GT 1500 AND LT 2015 keV
(Planned) Mode 1 INCA high voltage start LE 1500 OR
INCA high voltage stop LE 1500 keV.
(In calibration) Mode 0 INCA high voltage start GE 1855
INCA high voltage stop GE 2015 keV."
^HEADER = ("MIMI_INCA_OUTCAL_2005_01.CSV", 1 ❮BYTES❯)
^SPREADSHEET = ("MIMI_INCA_OUTCAL_2005_01.CSV", 12107 ❮BYTES❯)
OBJECT = HEADER
RECORDS = 1
BYTES = 101
HEADER_TYPE = SPREADSHEET
DESCRIPTION = "Column names for the fields"
END_OBJECT = HEADER
OBJECT = SPREADSHEET
FIELDS = 5
FIELD_DELIMITER = COMMA
ROW_BYTES = 88
ROWS = 138
OBJECT = FIELD
NAME = "Start_UTC"
DATA_TYPE = "TIME"
FIELD_NUMBER = 1
BYTES = 21
DESCRIPTION = "start time of the data gap as a
UTC string in ISO 8601 format"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Start_ET"
DATA_TYPE = "TIME"
FIELD_NUMBER = 2
BYTES = 10
DESCRIPTION = "stop time in ephemeris seconds past J2000"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Stop_UTC"
DATA_TYPE = "TIME"
FIELD_NUMBER = 3
BYTES = 21
DESCRIPTION = "stop time of the data gap as a
UTC string in ISO 8601 format"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "Stop_ET"
DATA_TYPE = "TIME"
FIELD_NUMBER = 4
BYTES = 10
DESCRIPTION = "stop time in ephemeris seconds past J2000"
END_OBJECT = FIELD
OBJECT = FIELD
NAME = "OutofCal_Flag"
DATA_TYPE = "ASCII_INTEGER"
FIELD_NUMBER = 5
BYTES = 2
DESCRIPTION = "INCA calibration mode (0) indicates neutral
mode, planned (1) or unplanned (2) out of calibration period."
END_OBJECT = FIELD
END_OBJECT = SPREADSHEET
END
|