PDS_VERSION_ID                = PDS3                                          
DATA_SET_ID                   = "CO-E/J/S/SW-MIMI-2-CHEMS-UNCALIB-V1.1"       
PRODUCT_ID                    = "CPHA0_2002293_0004"                          
STANDARD_DATA_PRODUCT_ID      = "MIMI_CHEMS_PHA"                              
PRODUCT_TYPE                  = "DATA"                                        
PRODUCT_VERSION_ID            = "0004"                                        
PRODUCT_CREATION_TIME         = 2018-228T16:54:27                             
                                                                              
RECORD_TYPE                   = STREAM                                        
INTERCHANGE_FORMAT            = ASCII                                         
FILE_RECORDS                  = 2293                                          
                                                                              
START_TIME                    = 2002-293T00:00:00                             
STOP_TIME                     = 2002-293T23:59:59                             
NATIVE_START_TIME             = "88344111.248000"                             
NATIVE_STOP_TIME              = "88430535.142000"                             
SPACECRAFT_CLOCK_START_COUNT  = "1/1413764345.000"                            
SPACECRAFT_CLOCK_STOP_COUNT   = "1/1413850769.128"                            
                                                                              
INSTRUMENT_HOST_NAME          = "CASSINI ORBITER"                             
INSTRUMENT_HOST_ID            = "CO"                                          
MISSION_PHASE_NAME            = "SCIENCE CRUISE"                              
ORBIT_NAME                    = "N/A"                                         
TARGET_NAME                   = "SOLAR WIND"                                  
INSTRUMENT_NAME               = "MAGNETOSPHERIC IMAGING INSTRUMENT"           
INSTRUMENT_ID                 = "MIMI"                                        
DESCRIPTION                   = "                                             
    (P)ulse (H)eight (A)nalysis data for the CHEMS sensor of the MIMI         
    instrument on the Cassini spacecraft"                                     
                                                                              
^HEADER                       = ("CPHA0_2002293_0004.CSV", 1 ❮BYTES❯)         
^SPREADSHEET                  = ("CPHA0_2002293_0004.CSV", 845❮BYTES❯)        
MD5_CHECKSUM                  = "b366a080f70142e10b1a003746db6d57"            
                                                                              
OBJECT                        = HEADER                                        
  RECORDS                     = 7                                             
  BYTES                       = 844                                           
  HEADER_TYPE                 = SPREADSHEET                                   
  DESCRIPTION                 = "                                             
    This file contains multiple rows of information:                          
        Row 1 - Column headings as comma separated (CS) double quoted strings.
        Row 2 - Valid minimum values for each of the data columns (CS).       
        Row 3 - Valid maximum values for each of the data columns (CS).       
        Row 4 - Actual minimum values for each of the data columns (CS).      
        Row 5 - Actual maximum values for each of the data columns (CS).      
        Row 6 - Mean value of all data within each column (CS).               
        Row 7 - Standard Deviation of all data within each column (CS)."      
END_OBJECT                    = HEADER                                        
                                                                              
OBJECT                        = SPREADSHEET                                   
  ROWS                        = 2286                                          
  FIELDS                      = 20                                            
  ROW_BYTES                   = 242                                           
  FIELD_DELIMITER             = COMMA                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "PURPOSE"                                     
    FIELD_NUMBER              = 1                                             
    DATA_TYPE                 = CHARACTER                                     
    BYTES                     = 32                                            
    DESCRIPTION               = "                                             
       The PURPOSE field identifies the purpose or function of the data       
       contained in current row. Valid entries include:                       
       SCI - normal science data values                                       
       VALID_MIN - the inclusive or exclusive minimum value allowed for this  
       column                                                                 
       VALID_MAX - the inclusive or exclusive maximum value allowed for this  
       column                                                                 
       MIN - the minimum value for this column present in this product        
       MAX - the maximum value for this column present in this product        
       MEAN - the mean of the values in this column in this product, this     
       value will be rounded for integer columns                              
       STDEV - the standard deviation of the values in this column in this    
      product, this value will be rounded for integer columns"                
  END_OBJECT                  = FIELD                                         
  OBJECT                      = FIELD                                         
    NAME                      = "UTC"                                         
    FIELD_NUMBER              = 2                                             
    DATA_TYPE                 = CHARACTER                                     
    BYTES                     = 21                                            
    DESCRIPTION               = "                                             
       The time as YYYY-DOYTHH:MM:SS.HHH calculated using the starting        
       Ephemeris Time for this record"                                        
  END_OBJECT                  = FIELD                                         
  OBJECT                      = FIELD                                         
    NAME                      = "SCLOCK"                                      
    FIELD_NUMBER              = 3                                             
    DATA_TYPE                 = CHARACTER                                     
    BYTES                     = 16                                            
    DESCRIPTION               = "                                             
       SCLOCK in ticks calculated using the starting Ephemeris Time for this  
       record. The SCLOCK format is #/NNNNNNNNNN.FFF where                    
       # is the partition number                                              
       NNNNNNNNNN is the number of ticks since the beginning of the mission   
       FFF is the fine number of ticks as 1/256 of a second"                  
  END_OBJECT                  = FIELD                                         
  OBJECT                      = FIELD                                         
    NAME                      = "START_EPHEMERIS_S"                           
    FIELD_NUMBER              = 4                                             
    UNIT                      = SECOND                                        
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 20                                            
    VALID_MINIMUM             = -71063936                                     
    VALID_MAXIMUM             = 757339265                                     
    DESCRIPTION               = "                                             
      The J2000 ephemeris time in seconds at the beginning of the time period 
      for this record."                                                       
  END_OBJECT                  = FIELD                                         
  OBJECT                      = FIELD                                         
    NAME                      = "END_EPHEMERIS_S"                             
    FIELD_NUMBER              = 5                                             
    UNIT                      = SECOND                                        
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 20                                            
    VALID_MINIMUM             = -71063936                                     
    VALID_MAXIMUM             = 757339265                                     
    DESCRIPTION               = "                                             
      The J2000 ephemeris time in seconds at the end of the time period for   
      this record."                                                           
  END_OBJECT                  = FIELD                                         
  OBJECT                      = FIELD                                         
    NAME                      = "SPIN_COUNTER"                                
    FIELD_NUMBER              = 6                                             
    DATA_TYPE                 = ASCII_INTEGER                                 
    BYTES                     = 10                                            
    VALID_MINIMUM             = 0                                             
    VALID_MAXIMUM             = 16383                                         
    DESCRIPTION               = "                                             
      MIMI always organizes time by Spins, when Cassini is not in spin mode,  
      MIMI uses a commanded virtual spin period. This column is a counter     
      that increments with each spin or virtual spin. This counter resets     
      when MIMI undergoes certain operations like shutdown, and is not        
      sufficiently large that it will not roll over."                         
  END_OBJECT                  = FIELD                                         
  OBJECT                      = FIELD                                         
    NAME                      = "SECTOR"                                      
    FIELD_NUMBER              = 7                                             
    DATA_TYPE                 = ASCII_INTEGER                                 
    BYTES                     = 10                                            
    VALID_MINIMUM             = 0                                             
    VALID_MAXIMUM             = 15                                            
    DESCRIPTION               = "                                             
       Each spin is divided into 16 sectors. Sectors have no meaning with     
       regard to pointing. They are nothing more or less than segments of     
       time. This column contains the zero based index of the sector.         
      Sectors have special significance in that the beginning of a sector is  
      the only time that MIMI records the SCLOCK. All other times must be     
      calculated based on the subsector, and, where appropriate, microsector  
      values provided below. Times in this product were calculated in this    
      manner."                                                                
  END_OBJECT                  = FIELD                                         
  OBJECT                      = FIELD                                         
    NAME                      = "START_SECTOR_SCLOCK_MAJOR"                   
    FIELD_NUMBER              = 8                                             
    UNIT                      = COUNT                                         
    DATA_TYPE                 = ASCII_INTEGER                                 
    BYTES                     = 10                                            
    VALID_MINIMUM             = 0                                             
    VALID_MAXIMUM             = 4000000000                                    
    DESCRIPTION               = "                                             
      The value of the Spacecraft clock at the beginning of Sector during     
      which this record occurred. This, combined with subsector, and          
      microsector where appropriate, is the monotonic timestamp for the each  
      record. All other times are calculated from this time representation."  
  END_OBJECT                  = FIELD                                         
  OBJECT                      = FIELD                                         
    NAME                      = "SUBSECTOR"                                   
    FIELD_NUMBER              = 9                                             
    DATA_TYPE                 = ASCII_INTEGER                                 
    BYTES                     = 10                                            
    VALID_MINIMUM             = 0                                             
    VALID_MAXIMUM             = 15                                            
    DESCRIPTION               = "                                             
      Each sector is divided into 16 subsectors. Subsectors have no meaning   
      as far as pointing. They are nothing more or less than segments of      
      time."                                                                  
  END_OBJECT                  = FIELD                                         
  OBJECT                      = FIELD                                         
    NAME                      = "MICROSECTORS_COVERED"                        
    FIELD_NUMBER              = 10                                            
    DATA_TYPE                 = ASCII_INTEGER                                 
    BYTES                     = 10                                            
    VALID_MINIMUM             = 2                                             
    VALID_MAXIMUM             = 1024                                          
    DESCRIPTION               = "                                             
      Each subsector is divided into 16 microsectors. Microsectors have no    
      meaning as far as pointing. They are nothing more or less than segments 
      of time. This column is the number of microsectors over which this      
      record was recorded, i.e. 16 for one subsector, 32 for two subsectors,  
      256 for one sector, etc."                                               
  END_OBJECT                  = FIELD                                         
  OBJECT                      = FIELD                                         
    NAME                      = "SPIN_PERIOD_S"                               
    FIELD_NUMBER              = 11                                            
    UNIT                      = SECOND                                        
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 20                                            
    VALID_MINIMUM             = 680                                           
    VALID_MAXIMUM             = 3072                                          
    DESCRIPTION               = "                                             
      The spacecraft spin period in seconds. If the spacecraft is not in spin 
      mode, this is the virtual spin period used by the MIMI sensor to        
      determine the timing of data collection. This value is not very         
      reliable. It represents the 'nominal' spin period. When the spin period 
      is changing, it will not be very accurate."                             
  END_OBJECT                  = FIELD                                         
  OBJECT                      = FIELD                                         
    NAME                      = "STARING"                                     
    FIELD_NUMBER              = 12                                            
    DATA_TYPE                 = ASCII_INTEGER                                 
    BYTES                     = 10                                            
    VALID_MINIMUM             = 0                                             
    VALID_MAXIMUM             = 1                                             
    DESCRIPTION               = "                                             
      0 if the spacecraft is in spin mode, 1 if the not in spin mode."        
  END_OBJECT                  = FIELD                                         
  OBJECT                      = FIELD                                         
    NAME                      = "SENSOR_BITRATE"                              
    FIELD_NUMBER              = 13                                            
    DATA_TYPE                 = ASCII_INTEGER                                 
    BYTES                     = 1                                             
    VALID_MINIMUM             = 1                                             
    VALID_MAXIMUM             = 5                                             
    DESCRIPTION               = "                                             
  Describes the bit rate of each of the sensors (CHEMS, INCA, LEMMS).        
  1 = very low, 2 = low, 3 = medium, 4 = high, 5 = very high."               
  END_OBJECT                  = FIELD                                         
  OBJECT                      = FIELD                                         
    NAME                      = "INDEX_IN_SECTOR"                             
    FIELD_NUMBER              = 14                                            
    DATA_TYPE                 = ASCII_INTEGER                                 
    BYTES                     = 10                                            
    VALID_MINIMUM             = 0                                             
    VALID_MAXIMUM             = 30000                                         
    DESCRIPTION               = "                                             
      Automatically generated number to guarantee uniqueness in conjunction   
      with SCLOCK_S."                                                         
  END_OBJECT                  = FIELD                                         
  OBJECT                      = FIELD                                         
    NAME                      = "DPPS_LEVEL"                                  
    FIELD_NUMBER              = 15                                            
    DATA_TYPE                 = ASCII_INTEGER                                 
    BYTES                     = 10                                            
    VALID_MINIMUM             = 0                                             
    VALID_MAXIMUM             = 31                                            
    DESCRIPTION               = "                                             
      This field represents the step level for the calculation of E/Q for the 
      given duration."                                                        
  END_OBJECT                  = FIELD                                         
  OBJECT                      = FIELD                                         
    NAME                      = "ENERGY"                                      
    FIELD_NUMBER              = 16                                            
    DATA_TYPE                 = ASCII_INTEGER                                 
    BYTES                     = 10                                            
    VALID_MINIMUM             = 0                                             
    VALID_MAXIMUM             = 1023                                          
    DESCRIPTION               = "                                             
      This field represents the Channel number (0-1023) of measured energy    
  deposited in an SSD for the current PHA event.  "                          
  END_OBJECT                  = FIELD                                         
  OBJECT                      = FIELD                                         
    NAME                      = "TIME_OF_FLIGHT"                              
    FIELD_NUMBER              = 17                                            
    DATA_TYPE                 = ASCII_INTEGER                                 
    BYTES                     = 10                                            
    VALID_MINIMUM             = 0                                             
    VALID_MAXIMUM             = 1023                                          
    DESCRIPTION               = "                                             
      This field represents the Channel number (0-1023) of the measured time  
  of flight of the ion between the start MCP and the SSD for the current     
  PHA event."                                                                
  END_OBJECT                  = FIELD                                         
  OBJECT                      = FIELD                                         
    NAME                      = "SOLID_STATE_DETECTOR"                        
    FIELD_NUMBER              = 18                                            
    DATA_TYPE                 = ASCII_INTEGER                                 
    BYTES                     = 10                                            
    VALID_MINIMUM             = 0                                             
    VALID_MAXIMUM             = 3                                             
    DESCRIPTION               = "                                             
       This field Identifies the triggered SSD (1-3) for the current PHA      
   event.  A value of zero indicates that no SSD was triggered, and          
   that this is a double coincidence PHA event, not a triple coincidence     
   event.  Legal events with non-zero SSD ID will have the same value for    
   the SSD ID and the Start MCP ID."                                         
  END_OBJECT                  = FIELD                                         
  OBJECT                      = FIELD                                         
    NAME                      = "START_MICRO_CHANNEL_PLATE"                   
    FIELD_NUMBER              = 19                                            
    DATA_TYPE                 = ASCII_INTEGER                                 
    BYTES                     = 10                                            
    VALID_MINIMUM             = 0                                             
    VALID_MAXIMUM             = 3                                             
    DESCRIPTION               = "                                             
      This field Identifies the triggered MCP (1-3) for the current PHA event.
  The Telescope number is equal to  this value.                              
  A value of zero indicates an invalid event."                               
  END_OBJECT                  = FIELD                                         
  OBJECT                      = FIELD                                         
    NAME                      = "RANGE"                                       
    FIELD_NUMBER              = 20                                            
    DATA_TYPE                 = ASCII_INTEGER                                 
    BYTES                     = 10                                            
    VALID_MINIMUM             = 0                                             
    VALID_MAXIMUM             = 6                                             
    DESCRIPTION               = "                                             
       This field Identifies the mass vs. mass per charge range (0-6)         
   identified by the MIMI DPU for this PHA event.  A value of 7              
   indicates an invalid event.  See the Calibration data for an              
   interpretation of the values."                                            
  END_OBJECT                  = FIELD                                         
END_OBJECT                    = SPREADSHEET                                   
END