PDS_VERSION_ID = PDS3 DATA_SET_ID = "GO-J-EPD-2-REDR-HIGHRES-SECTOR-V1.0" RECORD_TYPE = STREAM OBJECT = TEXT PUBLICATION_DATE = 2022-06-08 NOTE = "ERRATA.TXT reflects any known deficiencies with files contained on volume GOMW_5001." END_OBJECT = TEXT END ERRATA This file contains a list of all deficiencies and irregularities that are known to exist at the time of production of the GOMW_5001 DVD. Any errors detected with this DVD will be published on subsequent volumes in this volume set. An online version of errors is also maintained at the PPI Node of the PDS. 1) Non-standard Pitch Angle Definition The data parameter described as "pitch angle" in the EPD data sets archived with PDS is actually the complement of what is typically defined to be the "pitch angle". The standard definition of pitch angle is the angle between the particle velocity and the magnetic field, whereas the "pitch angle" parameter provided in the EPD data is the angle between the detector look direction and the magnetic field. A new version of these data which includes pitch angle values which have been calculated according to the standard definition is available from PDS: Galileo EPD Calibrated Corrected Data Bundle, 2022 (https://doi.org/10.17189/n0dm-0014) 2) Document File Location The files referred to in the ^description pointer in all label files do not exist as named. They exist in the /DOCUMENT directory or one of its subdirectories, most likely /DOCUMENT/PROJECT. These files were listed for their usefulness as documentation. 3) Document File Versions In the /DOCUMENT/PROJECT directory, each sub-directory contains documents in Adobe PDF and ASCII text format. The ASCII text version of these documents are direct conversions of the PDF files. The ASCII versions are present to comply with PDS standards. In some cases these ASCII versions have been hand edited to insure their legibility. In many cases, however, this effort has not been made. It is highly recommended that the PDF versions be used when reading these documents, as ASCII has limitations that may prevent proper representation of the original format of these papers. In cases where the ASCII version must be used, note that many of these files may exceed the 80 column page width. It is advisable, therefore, to print any hardcopy of these documents in landscape mode. 4) New Static Standard Values PRODUCT_TYPE {DATA, GEOMETRY, CALIBRATION, DOCUMENT, CATALOG, SOFTWARE ANCILLARY, QLOOK_PLOT} HEADER object with HEADER_TYPE = TEXT. 5) Other non-standard practices File names are typically longer than 8.3 Directory names are typically longer than 8 characters. OBSERVATION_ID Formation does not comply with the formation rule specified in the PDSDD for Galileo data sets. The PDSDD definition is imaging specific. ^DESCRIPTION in PDS minimum labels points to the PDS label of the controling document(s) rather than the ascii version in the document directory as required by the standards. SPICE kernels in Extras directory. This is not the official archive of the SPICE kernels. Labels are not in good shape and there are no catalog files. DOCUMENT/*.TXT files might be described as ASCII text documents which would normally have a .ASC extension. In order to be more easily accessible to users, these files have been renamed with a .TXT extension. DOCUMENT/PROJECT/AR_SEF Uplink products included are stored in the DOCUMENT dir. DOCUMENT/PROJECT - Many documents have unusable ASCII forms created by PDF->ASCII converters. Doesn't comply with PDS standards. 6) Format files EPD_16.FMT, EPD_32.FMT, and EPD_64.FMT all previously described the time column as the start of an 11 minute average. These are high time resolution data with integration times ranging from 1.25s to 0.3s as describe by the data set description file: GO_EPD_HIGHRES_DS.CAT. - Issue corrected on Aug 9, 2016.