Trigger 44 Description

Sequence: C34, C35
Trigger 44 ( WBR cyclic turn-off)

This trigger is designed to terminate Wideband Receiver data acquisition, which was nominally started by one of the WBR cyclic triggers (42, 46, or 48). Data acquisition continues for all other receivers, dust detector is resumed, and the sounder is re-enabled. If the sounder was not running prior to the WBR cyclic, then this re-enabling has no effect. In addition, the MFR is switched back to the EX antenna.

Receiver Frequency Range Sensors Time between Snapshots
MFR 25 - 12 KHz EX, BZ 32 seconds