Trigger 64 Description

Sequence: All
Trigger 64 (HF WBR 1MHz with Bit-scoop)

The instrument is assumed to be operating in trigger 28 or trigger 80.

These triggers are designed to make use of the data-throttling capability in order to take advantage of unused bits (scoop-up) during low-rate periods. The hi-rate observation initiated by each of these triggers is specified as a "low priority" observation. The wideband data will only be acquired if the required number of bits has been scooped up. The target data volume must be specified in the trigger command.

Receiver  Frequency Range       Sensor          Cycle Time     Snapshot Size
--------  ---------------  ----------------  ----------------  -------------
MFR       25Hz-12KHz       EW,BZ               32.000 Seconds
Millisec  8.025MHz         EX                   2.500 Seconds      2048
WBR       1KHz-80KHz       HF (1MHz)            0.500 Seconds      4096