Trigger 56 Description

Sequence: All
Trigger 56 (STV LFR Noise Check)
This trigger is based on a mode used in a series of tests that were performed before launch, and is designed to test the noise detected by the LFR receiver.
Receiver  Frequency Range       Sensor          Cycle Time     Snapshot Size
--------  ---------------  ----------------  ----------------  -------------
LFR       1Hz-25Hz         EX,EW,BX,BZ         16.000 Seconds
MFR       25Hz-12KHz       EX,EW,BX,BZ         32.000 Seconds
WFR       1Hz-40Hz         EX                  32.000 Seconds       512
WFR       1Hz-40Hz         EW                  16.000 Seconds       512
WFR       1Hz-40Hz         BX                  16.000 Seconds       512
WFR       1Hz-40Hz         BZ                  16.000 Seconds       512

The trigger steps the LFR through the following antenna choices (the MFR is also
switched to the same antenna.  The data is dual routed through the LFR and the WFR.

128 seconds  EX
128 seconds  EW
128 seconds  BX
128 seconds  BZ