PDS_VERSION_ID = PDS3 RECORD_TYPE = STREAM OBJECT = TEXT PUBLICATION_DATE = 2011-03-23 NOTE = "S64_IEB.TXT describes the set of Instrument Expanded Blocks (IEBs) and individual commands used in the S64 sequence from 2010-10-11 through 2010-11-15, and a short description of each." END_OBJECT = TEXT END S64 RPWS Triggers ----------------- Tigger 0 Used to power the instrument on. Provides power to all the receivers. Tigger 12 700 bps Basic Survey Mode, used to initialize instrument Tigger 2E Put IEB Version Info to housekeeping & clear command counters Tigger 44 Stop WBR cyclic For more information see TRIG_44.TXT. Tigger 46 61-131 kbps compressed 80-KHz WBR cyclic For more information see TRIG_46.TXT. Tigger 80 3-Antenna Direction-finding mode For more information see TRIG_80.TXT. Tigger 8A 887 bps Survey Mode for Saturn Tour, toggling between 40-Hz and 2.5-KHz WFR For more information see TRIG_8A.TXT. Tigger A0 1150 bps SEDDF Mode for Saturn Tour, toggling between 40-Hz and 2.5-KHz WFR For more information see TRIG_A0.TXT. Tigger A4 173 kbps HRSED Mode for Saturn Tour, with 325-kHz WBR For more information see TRIG_A4.TXT. Tigger AC 75 kbps Ring Plane Crossing mode (RPXING) for Saturn Tour For more information see TRIG_AC.TXT. S64 RPWS Commands ----------------- 73HFR_ANALYSIS,E1FF Perform HFR Calibration 73MEM_TWEAK,HRP,WORD,0x0050,0x00NN,WBRC Sets Timing on WBR Captures 73MEM_TWEAK,LRP,WORD,0x0064,0x0000,SOND Disable Sounder 73MEM_TWEAK,LRP,WORD,0x0064,0xC01F,SOND Enable Sounder 73PS_RPWS,OFF Power RPWS off 73PS_RPWS,ON Power RPWS on 73RT_SLEEP,ACTIVE Prepare to exit low-power mode and power up receivers 73WRAP,(0x4045] Clear Internal Expanded Block (IEB) memory