PDS_VERSION_ID = PDS3 RECORD_TYPE = STREAM DATA_SET_ID = {"CO-V/E/J/S/SS-RPWS-4-SUMM-KEY60S-V1.0", "CO-V/E/J/S/SS-RPWS-2-REFDR-ALL-V1.0", "CO-V/E/J/S/SS-RPWS-3-RDR-LRFULL-V1.0", "CO-V/E/J/S/SS-RPWS-2-REFDR-WBRFULL-V1.0", "CO-V/E/J/S/SS-RPWS-2-REFDR-WFRFULL-V1.0"} PRODUCT_ID = "C11_TRIG_50" PRODUCT_VERSION_ID = "1.00" PRODUCT_TYPE = ANCILLARY INSTRUMENT_HOST_NAME = "CASSINI ORBITER" INSTRUMENT_HOST_ID = CO INSTRUMENT_NAME = "RADIO AND PLASMA WAVE SCIENCE" INSTRUMENT_ID = RPWS OBJECT = TEXT PUBLICATION_DATE = 2005-03-17 NOTE = " TRIG_50.TXT describes the RPWS instrument configuration for the High Frequency Receiver (HFR), the Medium Frequency Receiver (MFR), the Low Frequency Receiver (LFR), the Waveform Receiver (WFR), the Wideband Receiver (WBR), the Langmuir Probe (LP), the Sounder, and the onboard Dust detection algorithm when using Trigger 50." END_OBJECT = TEXT END Trigger 50 Description Sequence: All Trigger 50 (STV MFR Noise Check) This trigger is based on a mode used in a series of tests that were performed before launch, and is designed to test the noise detected by the MFR receiver. Receiver Frequency Range Sensor Cycle Time Snapshot Size -------- --------------- ---------------- ---------------- ------------- MFR 25Hz-12KHz EX,EW,BX,BZ 32.000 Seconds The antenna the MFR is attatched to is switched as shown below 128 seconds Fixed Ex 128 seconds Fixed EW 128 seconds Fixed Bx 128 seconds Fixed Bz 256 seconds Toggle Bx/Bz 256 seconds Toggle Ex/Bx 256 seconds Toggle Ex/Bz