Trigger 1 Description
Sequence: All
Trigger 1 (Internal Basic Survey Mode)
This mode is designed to provide a Survey with fast temporal resolution
and standard spectral resolution for periods when an IEB has not been loaded.
Periodic Waveform measurements are made. The onboard dust detector is activated,
using the EZ antenna. The entire RPWS frequency range (1 Hz - 16 MHz) is covered.
Receiver |
Frequency Range |
Sensors |
Time between Snapshots |
LFR |
1 - 25 Hz |
EX, BX |
16 seconds |
MFR |
25 - 12 KHz |
EX, BX |
32 seconds |
WFR |
.05 - 2.5 KHz |
EX, EW, BX, BY, BZ |
341 seconds |
HFR |
3.6 KHz - 16 MHz |
EX, EW |
9.875 seconds |
The HFR is in CMS mode (Composite Mode Survey). No direction-finding is done.
This mode is defined by:
Correlations Channels Integ. Size Frequency
Band Ant. Auto- Cross- per Band df Period Rep Steps kHz Start - Stop
---- ---- ----- ------ -------- -- ------ --- ----- ---- ------------
ABC 2E y y 16 n 1000 1 3.6-319 kHz
H1 2E n y 2 n 80 1 60 25 325k-1.8MHz
H2 1E n n 1 n 20 1 72 200 1.8M-16MHz
Bands ABC require 3.16 sec to complete, H1 requires 5.05 sec, and H2 requires 1.46 sec
for a total of 9.67 sec per sweep. Data collection and output limits the snapshot
time to 9.875 seconds.