Trigger 72 Description

Sequence: All
Trigger 72 mode
Receiver  Frequency Range       Sensor          Cycle Time     Snapshot Size 
--------  ---------------  ----------------  ----------------  -------------
LFR       1Hz-25Hz         EX,BX               32.000 Seconds          
MFR       25Hz-12KHz       EX,BZ               32.000 Seconds          
HFR       3.6KHz-16MHz     EX,EW               50.625 Seconds          
Millisec  125.000KHz       EX                   2.500 Seconds      2048
WFR       50Hz-2.5KHz      EX,EW,BX             0.000 Seconds       512
WFR       50Hz-2.5KHz      EX,EW,BX,BY,BZ      25.000 Seconds       512
WFR       1Hz-40Hz         EX,EW,BX            32.000 Seconds       512
WFR       50Hz-2.5KHz      EX,EW,BX,BY,BZ       0.000 Seconds       512
WBR       100Hz-10KHz      EX                   4.000 Seconds      2048
WBR       1KHz-80KHz       HF                   0.250 Seconds      4096


          Correlations Channels    Integ.           Size Frequency     
Band Ant. Auto- Cross- per Band df Period Rep Steps kHz  Start - Stop  
---- ---- ----- ------ -------- -- ------ --- ----- ---- ------------  
ABC   2E    y     n       32    n   1000  1              3.6-319KHz       
HF1   2E    y     n        8    n    160  1    162    25 0.100-4.150MHz   
HF2   2E    y     n        8    n     80  1    241    50 4.125-16.175MHz  

Bands ABC require 2.945 sec to complete, H1 requires 26.457 sec, and 
H2 requires 20.365 sec for a total of 49.767 sec per sweep.  The hfr 
cycle time is 50.625 seconds.