Trigger 64 Description
Sequence: All
Trigger 64 mode
Receiver Frequency Range Sensor Cycle Time Snapshot Size
-------- --------------- ---------------- ---------------- -------------
LFR 1Hz-25Hz EX,BX 32.000 Seconds
MFR 25Hz-12KHz EX,EW,BX,BZ 32.000 Seconds
LPswp N/A Langmuir Probe 16.000 Seconds
LPden N/A Langmuir Probe 16.000 Seconds
HFR 3.6KHz-16MHz EX,EW 56.000 Seconds
WFR 50Hz-2.5KHz EX,EW,BX,BY,BZ 25.000 Seconds 512
WBR 100Hz-10KHz EX 8.000 Seconds 2048
WBR 1KHz-80KHz EX 8.000 Seconds 2048
Correlations Channels Integ. Size Frequency
Band Ant. Auto- Cross- per Band df Period Rep Steps kHz Start - Stop
---- ---- ----- ------ -------- -- ------ --- ----- ---- ------------
ABC 2E y y 32 n 1000 1 3.6-319KHz
HF1 2E y y 4 n 160 1 70 25 0.250-2.000MHz
HF2 2E y y 1 n 80 1 70 200 2.025-16.025MHz
Bands ABC require 3.120 sec to complete, H1 requires 12.301 sec, and
H2 requires 6.266 sec for a total of 21.687 sec per sweep. The hfr
cycle time is 56.000 seconds.