Receiver | Frequency Range | Sensors | Time between Snapshots |
MFR | 25 - 12 KHz | EX, BZ | 32 seconds |
MFDR | 200 - 1400 Hz | EX, BX | 48 seconds |
WFR | 1 - 25 Hz | EX,EW,BX,BY,BZ | 48 seconds |
HFR | 3.6 KHz - 16 MHz | EX, EW | 16 seconds |
LP | N/A | Langmuir Probe | 640 seconds |
Sounder | 3.6 - 115 KHz | EX, EW | 600 seconds |
The HFR is in a modified "Composite Survey" mode, which now includes both auto- and cross-correlations for H1. This mode is defined by:
Correlations Channels Integ. Size Frequency Band Ant. Auto- Cross- per Band df Period Rep Steps kHz Start - Stop ---- ---- ----- ------ -------- -- ------ --- ----- ---- ------------ ABC 2E y y 16 n 500 1 3.6-319KHz HF1 2E y y 2 n 40 1 60 25 0.325-1.825MHz HF2 1E n n 1 n 40 1 72 200 1.825-16.225MHz Bands ABC require 1.580 sec to complete, H1 requires 2.852 sec, and H2 requires 2.534 sec for a total of 6.966 sec per sweep. The hfr cycle time is 16.000 seconds.
Every 600 seconds the HFR normal analyses are interrupted by a Sounder analysis. The Sounder operation has a duration of approximately 40 seconds. This Sounder analysis is defined by:
Sounder Mode: Ex AAA 1st Sounder Frequency: 0 last Sounder Frequency: 89 T1 delay: 5 milliseconds T2 delay: 5 milliseconds T3 delay: 15 milliseconds Passive Spectra: 2 Active Spectra: 2 No. of Cycles: 1 Sounder Output A: 3 Autos Sounder Output B: 3 AGCs