Trigger 54 Description

Sequence: C37, C38, ...
Trigger 54 ( SKR WBR cyclic turn-off)

This trigger is designed to terminate Wideband Receiver data acquisition, which was nominally started by the SKR WBR cyclic trigger (52). Data acquisition continues for all other receivers, dust detection is resumed, and the HFR analysis mode is re-enabled.

Receiver Frequency Range Sensors Time between Snapshots
HFR 3.6 KHz - 16 MHz EU, EV, EW 32 seconds


Other notes:

Since the assumed HFR mode is a direction-finding mode, such as Trigger 80 or 94, the time between snapshots for the HFR is restored to 32 seconds. This may be a problem if the background trigger had a different value for this, as is the case for the normal survey triggers, such as 8A, 8E, and A0.

Another HFR parameter which is restored is the H1 start frequency, which is restored to 325 KHz. This is usually not a problem, since that is the value for most HFR operating modes.