Ulysses mission and dust detector configuration, tests and other events are tabulated. See Gruen et al. (1995a) and Krueger etal. (1999a) for more details, and see Instrument Status and Confidence Level Note, Mission Status Data for corrections and qualifications.
START_TIME = 1990-10-06T00:00 STOP_TIME = 1995-12-14T15:00 ROWS = 89 COLUMNS = 10 RECORD_FORMAT = "(a14,2x,a1,1x,3(1x,a1),2x,4(a1,1x),1x,a41)"
Col | Name | Start Byte | Format |
---|---|---|---|
1 | NATIVE TIME | 1 | A14 |
2 | CHANNELTRON EVENT FLAG | 17 | A1 |
3 | ION EVENT FLAG | 19 | A1 |
4 | ELECTRON EVENT FLAG | 21 | A1 |
5 | ION COLLECTOR THRESHOLD | 24 | A1 |
6 | ELECTRON COLLECTOR THRESHOLD | 26 | A1 |
7 | CHANNELTRON THRESHOLD | 28 | A1 |
8 | ENTRANCE GRID THRESHOLD | 30 | A1 |
9 | CHANNELTRON VOLTAGE LEVEL | 33 | A1 |
10 | DDS STATUS NOTE | 36 | A44 |
NATIVE TIME -
Event time given in year, day of year,
hours and minutes in the general form: yyyy-dddThh:mm.
CHANNELTRON EVENT FLAG -
A flag denoting that an event may be
defined by a channeltron signal, in which case the flag is set to 1,
otherwise it is set to 0. When the instrument is off, the flag is set
to X, and when the setting is unknown, the flag is set to '?'.
ION EVENT FLAG -
A flag denoting that an event may be
defined by an ion signal, in which case the flag is set to 1,
otherwise it is set to 0. When the instrument is off, the flag is set
to X, and when the setting is unknown, the flag is set to '?'.
ELECTRON EVENT FLAG -
A flag denoting that an event may be
defined by an electron signal, in which case the flag is set to 1,
otherwise it is set to 0. When the instrument is off, the flag is set
to X, and when the setting is unknown, the flag is set to '?'.
ION COLLECTOR THRESHOLD -
Code (ICP) corresponding to the
threshold set for the positive ion charge impulse(Q_I) at the time of
impact.
ELECTRON COLLECTOR THRESHOLD -
Code (ECP) corresponding to the
threshold set for the electron charge impulse(Q_E) at the time of
impact.
CHANNELTRON THRESHOLD -
Code (CCP) corresponding to the
threshold set for the channeltron charge(Q_C) pulse at the time of
impact.
ENTRANCE GRID THRESHOLD -
Code (PCP) corresponding to the
threshold set for the entrance grid charge pulse(Q_P) at the time of
impact separately for positively and negatively charged particles.
CHANNELTRON VOLTAGE LEVEL -
Code (HV) corresponding to the
channeltron high voltage level(HV) set at the time of impact with
integers representing fixed voltage differences.
See Channeltron Voltage Level,
Confidence Level Note.
DDS STATUS NOTE -
Note concerning DDS or Ulysses
spacecraft status.
ICP|Q_I (Coulomb)
---+----------------
X | OFF
? | UNKN
0 | 1.0E-14
1 | 2.6E-14
2 | 5.8E-14
3 | 1.5E-13
ECP|Q_E (Coulomb)
---+----------------
X | OFF
? | UNKN
0 | -9.8E-15
1 | -2.4E-14
2 | -5.5E-14
3 | -1.4E-13
CCP|Q_C (Coulomb)
---+----------------
X | OFF
? | UNKN
0 | -1.8E-13
1 | -2.4E-13
2 | -5.2E-13
3 | -1.2E-12
PCP|Q_P (positive) (Coulomb)|Q_P (negative) (Coulomb)
---+------------------------+------------------------
X | OFF | OFF
? | UNKN | UNKN
0 | 9.4E-15 | -1.8E-14
1 | 2.3E-14 | -3.8E-14
2 | 5.0E-13 | -7.3E-14
3 | 1.2E-13 | -1.5E-13
HV|Voltage(Volts)
--+-------
X| OFF
?| UNKN
0| 200
1| 900
2| 1020
3| 1140
4| 1250