To obtain the latest version of this ERRATA.TXT file use the anonymous-ftp service at pdsppi.igpp.ucla.edu. Give your login name as "anonymous", but please provide your e-mail address when prompted for a password. Change to the PDS errata directory (cd pds/ERRATA/PV05), and transfer the file ERRATA.TXT (get ERRATA.TXT). Changes can also be found through our web site at http://www.igpp.ucla.edu/igpp/ditdos.exe through the data access system. CUM_INDX.TAB For the most up-to-date version of the CUM_INDX.TAB (a full index of files contained on all currently available PVO SEDR volumes) please check the anonymous-ftp directory at pds/ERRATA/PVO/CUM_INDX.TAB. ============================================================================== PV05_0001 to PV05_0003 The Electric Field Detector detects a signal that is not due to plasma waves that is synchronized with the sun. The phase of this signal is calculated at the spin period relative to the solar direction, using the pulse times provided by the project. If the phase is not in the range expected or if the phase is drifting there is a problem with the pulse times. For example the wrong spin period was used to extrapolate missing pulses over some extended interval. There are sun synchronized signals on several OEFD channels. The 5.4 kHz channel is used because of the generally low level of ambient (natural) signal at this frequency and because the sun induced spin signal is well defined at this frequency. When the UCLA magnetometer team corrected the pulse times, they either corrected or inserted the following fields as appropriate: msec_of_Fs, msec of-Rip and nearest_real_sun_pulse. The values for the other fields in such records were set to zero. A bug was found in the early version of the program. Below is a list of orbits that contain invalid values in some of the corrected or inserted records. These values should be ignored. This is not an exhaustive list. If you have any questions about the data, please contact the P.I. directly. --------------------------------------------------------------------- List of files with incorrect values: Filename Total # of Bad Data Records Bad Data Record Numbers cp0001.dat 48 0631-0635, 6091, 6386-6427 cp0002.dat 40 0196-235 cp0037.dat 9 7213, 7215-7222 cp0251.dat 1 2415 cp0331.dat 9 5009-5011, 6784-6789 cp0360.dat 32 0364-0380, 5784-5798 cp0361.dat 10 4312-4321 cp0365.dat 1 3770 cp0368.dat 1 4463 cp0372.dat 1 3637 cp0374.dat 1 0718 cp0379.dat 1 3323 cp0401.dat 1 6804 cp0403.dat 27 6693-6719 cp0407.dat 10 2947-2955, 3028 cp0408.dat 1 5232 cp0409.dat 8 2981-2988 cp0410.dat 1 6771 cp0412.dat 12 6200-6211 cp0413.dat 30 1223-1232, 2172-2181, 3844-3853 cp0414.dat 1 1556 cp0416.dat 10 1844-1853 cp0421.dat 1 0432 cp0425.dat 11 1281-1284, 4625-4631 cp0427.dat 1 4617 cp0428.dat 1 4589 cp0434.dat 2 1411, 4685 cp0446.dat 1 3042 cp0449.dat 1 4986 cp0451.dat 4 4985-4988 cp0457.dat 21 2926-2946 cp0462.dat 1 2902 cp0471.dat 8 2939-2946 cp0474.dat 6 1415-1420 cp0475.dat 1 1426 cp0476.dat 9 1384-1392 cp0479.dat 1 1401 cp0480.dat 1 1383 cp0484.dat 1 0607 cp0485.dat 7 1413-1419 cp0487.dat 2 1407, 4640 cp0491.dat 1 0535 cp0495.dat 1 4687 cp0496.dat 1 5090 cp0503.dat 2 1422, 6304 cp0519.dat 1 0650 cp0526.dat 2 0199, 3672 cp0533.dat 1 3727 cp0542.dat 2 1395, 2937 cp0569.dat 3013 4841-4852, 6117-9117 cp0601.dat 13 1459-1471 cp0635.dat 6 2700-2705 cp0698.dat 1 8810 cp0705.dat 1 7300 cp0710.dat 1 1936 cp0711.dat 1 7221 cp0712.dat 1 7307 cp0714.dat 1 7260 cp0721.dat 1 7498 cp0724.dat 2 1950, 2593 cp0737.dat 1 1471 cp0792.dat 1 3784 cp0865.dat 560 0001-719 ============================================================================== PV05_0001 to PV05_0008 Error in the directory /CATALOG/: The file CATALOG.CAT contains an older version of the MISSION.CAT and INSTHOST.CAT (SCRAFT.CAT) catalog templates. The revised versions include the Pioneer 12 and PVO information into a single template, with a more complete discussion of the Multiprobe breakup and timing. ============================================================================== PV05_0001 to PV05_0008 Error in the directory /DATA/LOGISTIC/ORB*/: The file SEDR.LBL in all ORB* sub-directories describes the format of the accompanying SEDR.TAB files incorrectly. ============================================================================== PV05_0001 to PV05_0008 Error in the directory /DATA/DOCUMENT/: The DOCUMENT_NAME described in the file SEDR.LBL was longer than the 60 character limit allowed by PDS Standards. ============================================================================== PV05_0001 to PV05_00XX Error in the directory /INDEX/: The files INDEX.TAB and CUM_INDX.TAB pre-date the PDS standards on index files. However, the format used on previous PV05 volumes will continue to be used on all subsequent volumes in order to maintain continuity over the entire PVO SEDR series. ============================================================================== PV05_0001 to PV05_0009 Error in the directory /CATALOG/: The file CATALOG.CAT has been superceded. In PVO5_0010 it was changed to include more informative MISSION and INSTHOST templates (PVO and PVOMP).