GE- 3/31/97

                           E6 Science Data Losses

048-08:07 ---> 089-16:46; Lost TFs in brackets[.....] Changes in Bold

 Time (GMT)  DSS  Reference     RT  Rcvd Events          Comments          Cause  Array
                               TFs                                                Ops
                              Lost  from
                                                                                  Related?
                                     PPT

 048-22:42    43  DR#           37    35 The sta had to  - Lost TFs            S       Yes
                  A01050                 reboot the      [57005->57041]
 ->                                      FSC,BTD, and    137 RTS & 5
 049-01:27                               FCD to recover  Priority VCDUs
                                         the DGT from a
                                         FSC failure.    - ***Recovered
                                                         TFs [57005 &
                                                         57006, 56009 ->
                                                         57041] from FSR
                                                         tape
                                                         re-processing

 049-17:22    14  DR#            3     0 Power glitch    - Lost TFs            F        No
                  G01080                 at SPC10.       [57152->57154]
 -> 17:43                                                12 RTS VCDUs

 050-19:16    43  DR#            4     0 No FSC cross    - Lost TFs            S       Yes
                  A01054                 correlation of  [57419->57422]
 -> 19:33                                DSS42. No       12 RTS VCDUs
                                         action was
                                         taken to
                                         achieve good
                                         cross
                                         correlation.

 051-00:03    49  DR #           5     0 Bad router      - Lost TFs            S       Yes
                  A01057                 interface       [57502->57506]
 -> 00:20                                between DSS49   20 RTS VCDUs
                                         and SPC40. The
                                         router was
                                         reset to
                                         restore the
                                         interface.

 051-00:23    49  DR#            4     0 Bad router      - Lost TFs            S       Yes
                  A01057                 interface       [57508->57511]
 -> 00:37                                between DSS49   16 RTS VCDUs
                                         and SPC40. The
                                         router was
                                         reset to
                                         restore the
                                         interface.

 051-13:42   63                  3     0 - Unknown       - Lost TF             U        No
                                                         [57627] 63
 -> 14:51     &                          - BRC 20-8bps
                                         at 14:54        - Lost TF [
              14                                         57628]
                                                         unrecoverable by
                                                         either DSS

                                                         - Lost TF
                                                         [57629] 14

                                                         10 RTS & 2
                                                         Priority VCDUs

 051-20:23    43  DR#            2     0 - Missed the    - Lost TFs            U        No
                  A01059                 BRC 60-80bps    [[57669 & 57670]
 -> 20:30                                                8 RTS VCDUs
                                         Europa
                                         Encounter
                                         occurred at
                                         17:56

 051-20:44    43  DR#            2     0 - The           - Lost TFs           PD        No
                  A01058                 scheduled       [57679 & 57680]
 -> 21:05                                uplink          7 RTS & 1
                                         transfer at     Priority VCDUs
                                         19:05 between
                                         DSS14 & DSS43
                                         was delayed 10
                                         minutes. 6 TFs
                                         were lost of
                                         which 2
                                         contained
                                         non-fill tlm.

 052-00:59    43  DR#            1     0 PCG tones,      - Lost TF            PD        No
                  A01060                 used for VLBI,  [57738] 4 RTS
                                         were turned     VCDUs
                                         on.

 052-04:52    43  DR#            1     0 - Unknown       - Lost TFs            U        No
                  A01059                                 [57789] 4 RTS
                                         - BRC 60-32bps  VCDUs

 052-19:28    43                 1     1 - Unknown       - Lost TF             U        No
                                                         [57867] 4 RTS
                                         - This is       VCDUs
                                         approximately
                                         the same time
                                         that the T-1
                                         was released
                                         by GSFC.

 052-19:55    43  DR#            7     0 - The DGT T-1   - Lost TFs           PN        No
                  N42325                 was released    [57873->57879]
 -> 20:16                                to the carrier  28 RTS VCDUs
                                         without
                                         authorization

                                         - The carrier
                                         returned the
                                         T-1 at 20:45z.

 052-23:54    43                 1     1 - LOS going     - Lost TF            PP        No
                                         1-way           [57941] 1 RTS &
                                                         1 Priority VCDUs
                                         - PWS fill not
                                         scheduled
                                         until 23:56z

 054-20:29    43                 1     0 Missed BRC      - Lost TF             U         U
                                         80->120bps.     [58400] 4 RTS
                                                         VCDUs

 Time (GMT)  DSS  Reference     RT  Rcvd Events          Comments          Cause  Array
                               TFs                                                Ops
                              Lost  from
                                                                                  Related?
                                     PPT

 056-16:15    14                 1     0 Missed the      - Lost TF             U        No
                                         first non-fill  [58882] 2
                                         transfer frame  Priority VCDUs
                                         after
                                         egressing from
                                         the Europa
                                         occultation.

 056-19:29    43  DR#           16    16 The EFT lan in  - Lost TFs          GCF        No
                  N42372                 the GCF of      [58919 & 58920]
 -> 20:43                                BLDG 230 has a  8 RTS VCDUs
                                         bad fiber
                                         connector. The  [58926 & 58927]
                                         connector was   8 RTS VCDUs
                                         replaced to
                                         restore         [58929 -> 58932]
                                         operability     16 RTS VCDUs
                                         and dataflow.
                                                         [58934 -> 58937]
                                                         16 RTS VCDUs

                                                         [58939 -> 58942]
                                                         16 PB VCDUs

 057- 01:07   43  DR#            1     0 Unknown         - Lost TF             U         U
                  A01075                                 [59031] 1 PB & 1
                                                         RTS VCDUs

 057-17:53    14                 1     1 - Unknown       - Lost TF             U        No
                                                         [59190] 2 PB
                                         - TMU drivers   VCDUs
                                         off

 058-14:11    14  DR#            7     2 DSS14 was       - Lost TFs            W        No
                  G01867                 unable to go    [59455 -> 59461]
 -> 15:12                                to point at     26 PB & 2
                                         scheduled BOT   Priority VCDUs.
                                         due to high
                                         winds. After    ***TFs [59460 &
                                         winds abated    59461]
                                         the station     receovered in
                                         went to point   PPT***
                                         at 14:48z.

 059-04:24    43  DR#            2     0 DSS49 went to   - Lost TFs            W       Yes
                  A01082                 stow due to     [59680 & 59681]
 -> 04:34                                high winds and  8 PB VCDUs
                                         the FSC
                                         halted. The
                                         FSC was
                                         rebooted to
                                         restore
                                         operability.

 059-13:50    14                 1     1 Unknown         - Lost TF             U        No
                                                         [59741] 4 PB
                                                         VCDUs

                                                         ***Recovered in
                                                         the PPT***

 060-14:04    14  DR#            3     1 Unknown         - Lost TFs            U        No
                  G01875                                 [60038 -> 60040]
 -> 14:45                                                11 PB & 1
                                                         Priority VCDUs

                                                         ***TF [60040]
                                                         recovered in
                                                         PPT***

 060-20:34    49  DR#            1     0 DSS49 to stow   - Lost TF             W       Yes
                  A01086                 due to high     [60113] 4 PB
                                         winds           VCDUs

 060-21:29    49  DR#            9     0 DSS49 to stow   - Lost TFs            W       Yes
                  A01086                 due to high     [60137 -> 60142]
 -> 21:42                                winds           23 PB & 1
                                                         Priority VCDUs
 21:45
                                                         - Lost TFs
 -> 21:49                                                [60144 & 60145]
                                                         8 PB VCDUs
 21:52
                                                         - Lost TF
                                                         [60147] 4 PB
                                                         VCDUs

 060-22:01    43  DR#           16     0 Inclement       - Lost TFs            W        No
                  A01088                 weather- rain,  [60150 -> 60165]
 -> 22:55                                and SNT > 30 K  62 PB & 2
                                                         Priority VCDUs

 061-01:19    43  DR#            6     0 Inclement       - Lost TFs            W        No
                  A01088                 weather- rain,  [60208 -> 60213]
 -> 01:39                                and SNT > 30 K  24 PB VCDUs

 061-04:16    43  DR#            1     0 Lightning       - Lost TF             W        No
                  A01089                 strike          [60260] 4 PB
                                         disabled the    VCDUs
                                         Ultra-Cone
                                         maser. The
                                         maser was
                                         reset to
                                         restore to
                                         operability.

 061-17:29    14                 1     1 Unknown         - Lost TF             U        No
                                                         [60364] 4 PB
                                                         VCDUs

 062-02:49    43                 1     1 Unknown         - Lost TF             U        No
                                                         [60535] 4 PB
                                                         VCDUs

 063-19:10    43  DR#            3     3 The GTC was     - Lost TFs            S        No
                  A01095                 reset in an     [60967 -> 60969]
 -> 19:24                                attempt to      12 PB VCDUs
                                         restore 3-12G
                                         DGT monitor.
                                         The attempt
                                         was
                                         unsuccessful.

 Time (GMT)  DSS  Reference     RT  Rcvd Events          Comments          Cause  Array
                               TFs                                                Ops
                              Lost  from
                                                                                  Related?
                                     PPT

 063-19:51    43  DR#            3     3 The BTD halted  - Lost TFs            S        No
                  A01095                 operation and   [60978 -> 60980]
 -> 20:01                                needed to be    11 PB & 1
                                         reset after     Priority VCDUs
                                         the earlier
                                         GTC reset to
                                         restore
                                         operability.

 063-21:33    49  DR#            4     0 DSS49 to stow   - Lost TFs            W       Yes
                  A01097                 due to high     [61019 -> 61024]
 -> 21:43                                winds from      15 PB & 1
                                         063-21:30 to    Priority VCDUs
                                         064-01:25

 064-20:04    49  DR#            1     0 - DSS49 was     - Lost TF             A       Yes
                  A01099                 unable to go    [61286] 4 PB
                                         to point due    VCDUs
                                         to unspecified
                                         computer
                                         problems.

                                         - BRC 60-80bps

 064-20:55    49  DR#            1     0 DSS49 to stow   - Lost TF             W       Yes
                  A01101                 due to high     [61299] 4 PB
                                         winds from      VCDUs
                                         20:53 to EOT

 065-10:08    63  DR#            1     1 Unknown         - Lost TF             U        No
                  L00923                                 [61404] 4 PB
                                                         VCDUs

 066-04:21    43  DR#           14     0 - The Antenna   - Lost TFs            A       Yes
                  A01104                 Servo           [61657 -> 61670]
 -> 05:54                                Controller at   53 PB & 2
                                         DSS43 failed.   Priority VCDUs
                                         No restoral
                                         prior to EOT
                                         at 05:50z.

 066-18:09    14  DR#           47     0 DSS14 utilized  - Lost TFs           PD        No
                  N42464                 the incorrect   [61757 -> 61803]
 -> 20:35                                set of          184 PB & 4
                                         predictions     Priority VCDUs
                                         for this
                                         support; the
                                         predictions
                                         did not
                                         include any
                                         BRC's past the
                                         BRC to 40bps.

 068-05:11    43                 1     1 Unknown         - Lost TF             U         U
                                                         [62264] 3 PB & 1
                                                         Priority VCDUs

 068-13:23    63                 1     1 - Unknown       - Lost TF             U        No
                                                         [62327] 4 PB
                                         - BRC           VCDUs
                                         32->20bps
                                         missed by
                                         incoming DSS14
                                         as well

 069-18:44    43  DR#            2     0 - Unknown       - Lost TFs          SPA        No
                  A01113                                 [62673 & 62674]
 -> 18:51                                - Below range   4 PB, 3 RTS, & 1
                                         Pd/N0 at FSC    Priority VCDUs

 070-04:38    43  DR#            1     0 - Unknown       - Lost TF             U       Yes
                  A01114                                 [62859] 4 PB
                                         -BRC 60-40bps   VCDUs

 070-06:18    63                 2     0 DSS63 acquired  - Lost TF's           U        No
                                         the downlink    [62870 & 62871]
 -> 06:41                                after
                                         conclusion the
                                         scheduled PWS
                                         fill

 070-08:27    63  DR#            1     1 Unknown         - Lost TF             U        No
                  L00928                                 [62882] 3 PB & 1
                                                         Priority VCDUs

 070-19:52    43  DR#           35     0 The FSC         - Lost TFs            S       Yes
                  A01115                 halted. The     [62986 -> 63020]
 -> 221:12                               station         139 PB & 1
                                         rebooted the    Priority VCDUs
                                         FSC to restore
                                         operability.    *FSR tapes
                                                         requested***

 071-19:35    42  DR#            3     0 The GTC halted  - Lost TFs            S       Yes
                  A01118                 and required a  [63258 -> 63260]
 -> 19:52                                reboot to       12 PB VCDUs
                                         restore to
                                         operability.

 071-21:28    49  DR#            2     0 Commercial      - Lost TFs            F       Yes
                  A01123                 power           [63286 & 63287]
 -> 21:42                                interruption    7 PB & 1
                                         to DSS49        Priority VCDUs

 071-22:57    42  DR#            1     0 Unknown         - Lost TF             U       Yes
                  A01124                                 [63299] 3 PB & 1
                                                         Priority VCDUs

 071-23:52    49  70             1     0 DSS49 swapped   - Lost TF             F       Yes
                                         to diesel       [63307] 3 PB & 1
                                         power to        Priority VCDUs
                                         alleviate any
                                         further
                                         commercial
                                         power
                                         interruptions

 Time (GMT)  DSS  Reference     RT  Rcvd Events          Comments          Cause  Array
                               TFs                                                Ops
                              Lost  from
                                                                                  Related?
                                     PPT

 071-13:55    14  DR#            3     0 -The DGT at     - Lost TFs            U        No
                  G01900                 DSS14 was       [63410 -> 63412]
 -> 14:23                                declared red    11 PB & 1
                                         at BOT          Priority VCDUs
                                         (1315z).

                                         - The restoral
                                         action is
                                         unknown at
                                         this time.

 072-03:15    43  DR#            6     0 - All TFs lost  - Lost TFs          SPA        No
                  A01131                 during rate     [63600 & 63601,
 ->05:10                                 changes. This   63607, 63617&
                                         would be        63618, 63626]
                                         acceptable
                                         considering     4 Priority VCDUs
                                         that each rate
                                         change
                                         occurred
                                         during, or
                                         shortly after,
                                         a burn period.

                                         - rate change
                                         losses:
                                         80-60bps,
                                         60-40bps, &
                                         40-32bps
                                         respectively.

 072-11:56    63  DR#            1     0 - Lost rate     - Lost TF           SPA        No
                  L00937                 change during   [63661] 1
                                         burn period.    Priority VCDU

                                         - rate change
                                         loss: 32-20bps

 073-14:14    14  DR#            2     0 - Complex wide  - Lost TF [63672      F        No
                  G01907                 power outage    & 63673] 2
 -> 14:31                                                priority VCDUs

 073-16:48    14  DR#            2     0 -Unscheduled    - Lost TFs            F        No
                  G01907                 2-way mode      [63690 & 63691]
 -> 17:13                                change due to   3 Priority VCDUs
                                         earlier power
                                         outage.

 074-12:55    63                 1     1 Unknown         - Lost TF             U        No
                                                         [63948] 4 PB
                                                         VCDUs

 074-17:54    43  DR#            7     0 MEC halted      - Lost TF [63982      A       Yes
                  A01133                 operation.      -> 63988] 27 PB
 -> 18:21                                Station went    & 1 Priority
                                         to computer     VCDUs
                                         mode for
                                         antenna
                                         movement.

 075-05:45    63  DR#            3     3 The BTD halted  - Lost TFs            H        No
                  L00946                 operation and   [64188 -> 64190]
                                         the station     6 PB, 2
                                         rebooted to     Priority, & 1
                                         restore         RTS VCDUs
                                         operability.

 077-21:03    43  DR#            1     0 - Lost during   - Lost TF             U       Yes
                  A01139                 the rate        [64942] 4 PB
                                         change from     VCDUs
                                         120 to 80bps.
                                         No other
                                         obvious
                                         activities
                                         occurred
                                         during that
                                         timeframe.

                                         - May be prdx
                                         related.

 078-01:53    43  DR#            1     0 FSR1 timed      - Lost TF             S       Yes
                  A01140                 out. No         [65027] 4 PB
                                         operator        VCDUs
                                         action was
                                         necessary to
                                         recover the
                                         FSR.

 078-06:05    63  DR#            7     0 The antenna     - Lost TFs            A        No
                  L00953                 went to brake   [65076 -> 65084]
 -> 07:04                                due to "film    24 PB, 2 RTS, &
                                         height alarm    2 Priority VCDUs
                                         on pad #1".
                                         The debris was
                                         cleared
                                         without
                                         maintenance
                                         intervention.

 078-11:46    63                 1     1 Unknown         - Lost TF             S        No
                                                         [65126] 4 PB
                                                         VCDUs

 078-13:16    14  DR#            1     1 - Unknown       - Lost TF             U        No
                  G01936                                 [65136] 4 PB
                                         - rate change   VCDUs
                                         20-32bps

 078-16:56    14  DR#            1     1 - Unknown       - Lost TF             U        No
                  G01937                                 [65164] 4 RTS
                                                         VCDUs

 078-17:30    43  DR#            1     0 FSC carrier     - Lost TF             S       Yes
                  A01142                 spectrum        [65169] 4 RTS
                                         reflected all   VCDUs
                                         zeros. The
                                         station
                                         rebooted the
                                         FSC to restore
                                         operability.

 079-18:56    43                 1     0 - Unknown       - Lost TF             U       Yes
                                                         [65509] 4 RTS
                                         - DSS49 was     VCDUs
                                         entered into
                                         the array 4
                                         minutes and 23
                                         seconds after
                                         the rate
                                         change from
                                         80-120bps.

                                         - Close out
                                         pending

 Time (GMT)  DSS  Reference     RT  Rcvd Events          Comments          Cause  Array
                               TFs                                                Ops
                              Lost  from
                                                                                  Related?
                                     PPT

 079-21:30    43  DR#            1     0 - Unknown       - Lost TF             U       Yes
                  A01148                                 [00036] 3 RTS &
                                         - rate change   1 Priority VCDUs
                                         80-120bps

 080-12:02    63  DR#            1     1 - Unknown       - Lost TF             S        No
                  L00959                                 [00234] 4 RTS
                                                         VCDUs

 080-12:19    63  DR#            1     0 - Unknown       - Lost TF             U       No
                  L00959                                 [00236] 3 RTS &
                                         -rate change    1 Priority VCDUs
                                         32-20bps

 080-12:46    63  DR#            1     0 - Unknown       - Lost TF [00238      U        No
                  L00959                                 & 00239] 7 RTS &
                                         - rate change   1 Priority VCDUs
                                         20-32bps

 081-18:25    43  DR#            1     1 - Unknown       - Lost TF             U       Yes
                  A01156                                 [00649] 4 PB
                                         - Missed rate   VCDUs
                                         change
                                         80-120bps

 081-19:34    43  DR#           40    40 - The FSC core  - Lost TFs            S       Yes
                  A01155                 process died    [00679 -> 00718]
 -> 20:49                                at the rate     134 PB, 16 RTS,
                                         change          & 2 Priority
                                         120-160bps.     VCDUs.
                                         The FSC was
                                         power cycled    ***Recovered
                                         to restore      from FSR tape
                                         operability.    reprocessing***

                                         - **FSR tapes
                                         requested**

 081- 21:23   14  DR#G01950      2     0 - DSS14 was     - Lost TFs           PP       Yes
                                         scheduled       [00734 & 00735]
 -> 21:28                                incorrectly,    8 PB VCDUs
                                         they were
                                         scheduled past
                                         EOT.

                                         - The FSC was
                                         unable to
                                         process the
                                         two frames due
                                         to predicted
                                         vs. actual
                                         supported
                                         array
                                         elements.

 082-12:52    63                 1     0 - Unknown       - Lost TF             U        No
                                                         [00959] 4 RTS
                                         - last valid    VCDUs
                                         TF @ 12:44 and
                                         EOT at 13:00

                                         - BR= 32bps

 082-23:32    43  DR#            2     0 The FSR1 tone   - Lost TF [01142      H       Yes
                  A01159                 rotator halted  & 01143] 6 PB &
 -> 23:36                                operation. It   2 RS VCDUs
                                         autonomously
                                         restored
                                         itself.

 083-04:35    43  DR#            2     0 The FSC         - Lost TF             S       Yes
                  A01160                 halted. The     [01245] 3 PB & 1
                                         station was     Priority VCDUs
                                         unable to
                                         restore prior
                                         to EOT at
                                         04:55.

                                         - **FSR tapes
                                         requested**

 083-12:16    63  DR#            1     1 Unknown         - Lost TF             S        No
                  L00946                                 [01296] 3 RTS &
                                                         1 Priority VCDUs

 083-18:06    43  DR#            1     0 - Unknown       - Lost TF             U       Yes
                  A01162                                 [01351] 4 PB
                                         - Rate change   VCDUs
                                         80-120bps

 083-19:05    43  DR#           76    75 - A bug within  - Lost TFs            S       Yes
                  A01163                 the FSC code    [01377 -> 01453]
 -> 21:26                                was isolated    263PB, 36 RTS, &
                                         by the DGT      4 Priority
                                         Task. A point   VCDUs.
                                         build fix was
                                         installed in
                                         the FSC and
                                         the frames
                                         reprocessed.
                                         Kim Simpson
                                         has the
                                         recovered
                                         frames on
                                         tape.

 083-22:02    43                 1     0 - Unknown       - Lost TF             U       Yes
                                                         [01470] 4 PB
                                                         VCDUs

 084-17:56    43  DR#            1     0 - Unknown       - Lost TF             U       Yes
                  A01165                                 [01729] 4 PB
                                         - rate change   VCDUs
                                         80-120bps

 084-19:02    43                 1     0 - This was a    - Lost TF           SPA        No
                                         scheduled fill  [01759] 1 PB
                                         period during   VCDU
                                         the rate
                                         change of
                                         120-160bps.
                                         DSS43 acquired
                                         the first TF
                                         at 19:04 one
                                         VCDU past the
                                         scheduled two
                                         TFs of fill.

 Time (GMT)  DSS  Reference     RT  Rcvd Events          Comments          Cause  Array
                               TFs                                                Ops
                              Lost  from
                                                                                  Related?
                                     PPT

 084-20:43    43  DR#            1     0 - Unknown       - Lost TF             U       Yes
                  A011665                                [01818] 4 PB
                                         - rate change   VCDUs
                                         160-120bps

 085-05:15    63                 1     1 - Unknown       - Lost TF             S        No
                                                         [02003] 1
                                         - This frame    Priority VCDU
                                         was not
                                         received
                                         during real
                                         time, but was
                                         in the .fcd
                                         PPT file.

 085-18:40    43  DR#            1     0 - Unknown       - Lost TF             U       Yes
                  A01167                                 [02128] 4 PB
                                         - Rate change   VCDUs
                                         80-120bps

 085-19:42    43                 1     0 - Rate change   - Lost TF           SPA        No
                                         120-160bps.     [02155] 1 PB
                                                         VCDU
                                         - The fill
                                         period starts
                                         one VCDU time
                                         early causing
                                         the loss of
                                         the first VCDU
                                         of Science
                                         data coming
                                         out of the
                                         scheduled fill
                                         period. Eight
                                         VCDUs of fill
                                         are scheduled
                                         for a
                                         120-160bps
                                         rate change.

 086-02:22    49  DR#            3     0 - DSS49 to      - Lost TFs            W       Yes
                  A01168                 stow due to     [02336 -> 02338]
 -> 02:32                                high winds.     9 PB, 2 RTS, & 1
                                                         Priority VCDUs
                                         - 120-80bps
                                         rate change

 087-18:18    43  DR#            2     0 - Unknown       - Lost TFs            U       Yes
                  A01172                                 [02754 & 02756]
 -> 18:23                                - Rate change   8 PB VCDUs
                                         80-120bps

 087-19:06    43  DR#            1     0 - Rate change   - Lost TF           SPA        No
                  A01172                 120-160bps      [02774] 1 RTS
                                                         VCDU

 087-21:17    43  DR#            3     0 - Thruster      - Lost TFs          SPA        No
                  A01173                 flush activity  [02844 -> 02846]
 -> 21:24                                                1 RTS & 1
                                                         Priority VCDUs

 087-22:43    43  DR#            2     0 - The MEC       - Lost TFs            A       Yes
                  A01174                 inoperative.    [02882 & 02883]
 -> 22:48                                The MEC was     1 RTS & 1
                                         reset to        Priority VCDUs
                                         restore
                                         operability.

 088-18:46    43  DR#            1     0 - Rate change   - Lost TF             U       Yes
                  A01175                 80-120bps       [03143] 2 RTS
                                                         VCDUs

 089-07:19    63                 2     0 The ACE         - Lost TFs          UPA        No
                                         requested the   [03333 & 03334]
 -> 07:33                                station         7 RTS & 1
                                         perform a       Priority VCDUs
                                         resweep of the
                                         uplink after
                                         noting
                                         incorrect
                                         parameters in
                                         the original
                                         uplink sweep.
                                         The original
                                         uplink sweep
                                         did appear to
                                         get into the
                                         spacecraft.

                                         The E6
                                         sequence ended
                                         on 089/16:46

 TOTAL                         453   196

                                         Total Science   10172
                                         Frames:

                                         Total Frames    12111
                                         (including
                                         Fill):

PP - Procedural (Project) Transfer Frames #s lost in brackets [.........]

PD - Procedural (DSN) F - Facility problem (e.g. power failure)

H - DGT H/W Related/Failure U - Unknown

A - Antenna Problem W - Weather (e.g. Parkes stow due to high winds)

S - DGT S/W Related; Error or newly understood
idiosyncracy/workaround/constraint

SA - Spacecraft anomaly and recovery actions

UPA - Unscheduled project action

SPA - Scheduled Project action

PN - Procedural (Nascom)

GCF- GCF hardware/software anomaly