Trigger 68 Description
Sequence: All
Trigger 68 (Langmuir Probe Cylinder Check)
This trigger steps through a series of settings of the LP while attatched to the
cylinders. After the LP tests, the instrument is put into Trigger 12
Receiver Frequency Range Sensor Cycle Time Snapshot Size
-------- --------------- ---------------- ---------------- -------------
MFR 25Hz-12KHz EX,BZ 32.000 Seconds
LPden N/A Langmuir Probe 16.000 Seconds See Below
LP Density Setup Duration
---------------- ----------
DAC 1 0x00 on Ex- 64 Seconds
DAC 1 0x11 on Ex- 64 Seconds
DAC 1 0x22 on Ex- 64 Seconds
DAC 1 0x33 on Ex- 64 Seconds
DAC 1 0x44 on Ex- 64 Seconds
DAC 1 0x55 on Ex- 64 Seconds
DAC 1 0x66 on Ex- 64 Seconds
DAC 1 0x77 on Ex- 64 Seconds
DAC 1 0x88 on Ex- 64 Seconds
DAC 1 0xAA on Ex- 64 Seconds
DAC 1 0xBB on Ex- 64 Seconds
DAC 1 0xCC on Ex- 64 Seconds
DAC 1 0xDD on Ex- 64 Seconds
DAC 1 0xEE on Ex- 64 Seconds
DAC 1 0xFF on Ex- 64 Seconds
DAC 1 0x00 on Ex+ 64 Seconds
DAC 1 0x11 on Ex+ 64 Seconds
DAC 1 0x22 on Ex+ 64 Seconds
DAC 1 0x33 on Ex+ 64 Seconds
DAC 1 0x44 on Ex+ 64 Seconds
DAC 1 0x55 on Ex+ 64 Seconds
DAC 1 0x66 on Ex+ 64 Seconds
DAC 1 0x77 on Ex+ 64 Seconds
DAC 1 0x88 on Ex+ 64 Seconds
DAC 1 0xAA on Ex+ 64 Seconds
DAC 1 0xBB on Ex+ 64 Seconds
DAC 1 0xCC on Ex+ 64 Seconds
DAC 1 0xDD on Ex+ 64 Seconds
DAC 1 0xEE on Ex+ 64 Seconds
DAC 1 0xFF on Ex+ 64 Seconds
Range Check CYBFR -4.69V 64 Seconds
Range Check CYBFR +4.65V 64 Seconds
Range Check CYBMR -4.69V 64 Seconds
Range Check CYBMR +4.65V 64 Seconds
Sphere/Cylinder Interaction Check EX+ @ -10V AD->Sphere 64 Seconds
Sphere/Cylinder Interaction Check EX+ @ -10V AD->EX+ (ADCP2) 64 Seconds
Sphere/Cylinder Interaction Check EX+ @ +10V AD->Sphere 64 Seconds
Sphere/Cylinder Interaction Check EX+ @ +10V AD->EX+ (ADCP2) 64 Seconds
Trigger 12