Trigger BA Description

Sequence: All
Trigger BA mode
Receiver  Frequency Range       Sensor          Cycle Time     Snapshot Size 
--------  ---------------  ----------------  ----------------  -------------
LFR       1Hz-25Hz         EX,BX               32.000 Seconds          
MFR       25Hz-12KHz       EX,EW,BZ            32.000 Seconds          
Millisec  325.000KHz       EX                   2.500 Seconds      2048
Millisec  225.000KHz       EX                   2.500 Seconds      2048
HFR       3.6KHz-16MHz     EX,EW               64.000 Seconds          
WFR       1Hz-40Hz         EX,EW,BX,BY,BZ       0.000 Seconds      2048
WFR       50Hz-2.5KHz      EX,EW,BX,BY,BZ       0.000 Seconds      2048
WBR       100Hz-10KHz      EX                   0.125 Seconds      2048


          Correlations Channels    Integ.           Size Frequency     
Band Ant. Auto- Cross- per Band df Period Rep Steps kHz  Start - Stop  
---- ---- ----- ------ -------- -- ------ --- ----- ---- ------------  
ABC   2E    y     y       16    n   1000  1              3.6-319KHz       
HF1   2E    y     y        2    n     20  1     60    25 0.325-1.825MHz   
HF2   1E    n     n        1    n     10  1     72   200 1.825-16.225MHz  

Bands ABC require 3.160 sec to complete, H1 requires 1.573 sec, and 
H2 requires 0.886 sec for a total of 5.619 sec per sweep.  The hfr 
cycle time is 64.000 seconds.