/* LRFC_DATA_QUALITY.FMT */
/* */
OBJECT = COLUMN
NAME = ENGINEERING_DATA
DATA_TYPE = MSB_BIT_STRING
START_BYTE = 13
BYTES = 4
DESCRIPTION = "This field contains the sensor ID number and
data quality status. Bits will be added as
sources of interferance, telemetry errors,
etc. are identified. Individual data values
within a capture are marked by multiplying
the original measurement by negative one."
OBJECT = BIT_COLUMN
NAME = VALID_DATA_FLAG
BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BIT = 1
BITS = 1
DESCRIPTION = "This is the generic flag for data of questional
value, due to unforeseen events: telemetry
corruption during transmit/receive,
compression/decompression errors, etc. All
or part of the data set may still be of valid
measurements, but it is left up to the user to
decide.
0 = valid data
1 = data of questional value"
END_OBJECT = BIT_COLUMN
OBJECT = BIT_COLUMN
NAME = HFR_SOUNDER_ACTIVE
BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BIT = 2
BITS = 1
DESCRIPTION = "Indicates if the high frequency receiver
sounder was active during the data capture.
0 = hfr sounder inactive
1 = hfr sounder active"
END_OBJECT = BIT_COLUMN
OBJECT = BIT_COLUMN
NAME = LP_RAW_SWEEP_ACTIVE
BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BIT = 3
BITS = 1
DESCRIPTION = "Indicates if the langmuir probe raw
sweep was active during the data capture.
0 = lp raw sweep inactive
1 = lp raw sweep active"
END_OBJECT = BIT_COLUMN
OBJECT = BIT_COLUMN
NAME = GROUND_PRODUCED_DATA
BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BIT = 4
BITS = 1
DESCRIPTION = "Indicates if the data was ground produced data
from flight data. For example, the wfr time
series data was transformed into its
frequency components to produce lfdr data."
END_OBJECT = BIT_COLUMN
OBJECT = BIT_COLUMN
NAME = SENSOR_NUMBER
BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BIT = 29
BITS = 4
DESCRIPTION = "Sensor Number identifies which
sensor was connected to the receiver.
0=Ex 4=Bx 8=Hf
1=Eu 5=By 11=Lp
2=Ev 6=Bz
3=Ew"
END_OBJECT = BIT_COLUMN
END_OBJECT = COLUMN
|